SwePub
Sök i LIBRIS databas

  Extended search

L773:0195 6701 OR L773:1532 2939
 

Search: L773:0195 6701 OR L773:1532 2939 > Evaluating the effe...

Evaluating the effect of Novarerus NV800 air purifier units during orthopaedic surgery to reduce bioburden in the air

Lytsy, Birgitta, 1968- (author)
Uppsala universitet,Klinisk mikrobiologi
Ljungqvist, Bengt, 1946 (author)
Chalmers tekniska högskola,Chalmers University of Technology,Chalmers Univ Technol, Bldg Serv Engn, Gothenburg, Sweden.
Nordenadler, Johan (author)
Karolinska Institutet,Karolinska Inst, Clin Sci Intervent & Technol, Funct & Technol, Solna, Sweden.
show more...
Reinmüller, Berit, 1939 (author)
Chalmers tekniska högskola,Chalmers University of Technology,Chalmers Univ Technol, Bldg Serv Engn, Gothenburg, Sweden.
show less...
 (creator_code:org_t)
Elsevier BV, 2022
2022
English.
In: Journal of Hospital Infection. - : Elsevier BV. - 0195-6701 .- 1532-2939. ; 130, s. 108-111
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: A locally installed air purifier unit (Novaerus Protect 800) has been shown to reduce the air bioburden in an intensive care unit and the incidence of healthcare-associated infections. Aim: To explore whether this type of air purifying unit could reduce bacterial concentrations in the air of an operating room (OR) during orthopaedic surgery, thereby reducing the risk of surgical site infections. Methods: In this prospective experimental study, undertaken in 2018, three air purifying units were installed in an OR in a Swedish hospital in 2018. The air was actively sampled during 11 operations by a slit-to-slit agar impactor with the air purifying units either switched on or switched off. Air movements were visualized with the aid of smoke in mock-up studies. Findings: No significant difference in bacterial concentrations in air was found between the two conditions (air purifying units switched off or on) (P=0.54). Air movements around and above the surgical wound were disordered and resembled those of dilution mixing air. Conclusion: The three air purifying units installed in the OR did not reduce the airborne bacterial levels in the critical zone during orthopaedic surgery.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Infektionsmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Infectious Medicine (hsv//eng)

Keyword

Surgical site infection
Operating air bioburden
Air purifier
Operating theatre

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view