SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Hansson Kerstin)
 

Sökning: WFRF:(Hansson Kerstin) > (2015-2019) > Comparison of macro...

Comparison of macroscopic resorption time for a self-locking device and suture material in ovarian pedicle ligation in dogs

Hansson, Kerstin (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences
Ley, Charles (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences
Olsson, Ulf (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för energi och teknik,Department of Energy and Technology
visa fler...
Höglund, Odd (författare)
Swedish University of Agricultural Sciences,Sveriges lantbruksuniversitet,Institutionen för kliniska vetenskaper (KV),Department of Clinical Sciences,Resorbable Devices
visa färre...
 (creator_code:org_t)
 
2019-04-13
2019
Engelska.
Ingår i: Veterinary Record. - : Wiley. - 0042-4900 .- 2042-7670. ; 184
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A resorbable self-locking device (LigaTie) was developed to enable safe and easy surgical ligation of blood vessels. The aim of this study was to compare the long-term in vivo resorption of the device to a commercially available suture of equivalent material (Maxon) following ovarian pedicle ligation. After ovariohysterectomy follow-up ultrasound examinations were performed monthly on 21 dogs ligated with the device and 22 dogs ligated with the suture material until no hyperechoic remnants, acoustic shadowing or local tissue reactions were detected. In both groups, the ovarian pedicles gradually decreased in size. Ligation material was considered macroscopically resorbed when ultrasound showed no signs of the device or suture, ovarian pedicle or tissue reaction. Macroscopic resorption had occurred without signs of complications and was complete by four months for sutures and 5.5 months for the device. The results show that resorption time in vivo for the resorbable self-locking device is mildly longer than suture of the same material and that no complications of device resorption were detected, supporting that the resorbable self-locking device is safe for in vivo use.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Annan materialteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Other Materials Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hansson, Kerstin
Ley, Charles
Olsson, Ulf
Höglund, Odd
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Materialteknik
och Annan materialte ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Veterinary Recor ...
Av lärosätet
Sveriges Lantbruksuniversitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy