SwePub
Sök i LIBRIS databas

  Extended search

(WFRF:(Weber M.)) srt2:(1994)
 

Search: (WFRF:(Weber M.)) srt2:(1994) > Small animal imagin...

Small animal imaging with pinhole single-photon emission computed tomography

Strand, Sven-Erik (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Ivanovic, M (author)
Erlandsson, K (author)
show more...
Franceschi, D (author)
Button, T (author)
Sjogren, K (author)
Weber, D A (author)
show less...
 (creator_code:org_t)
1994
1994
English.
In: Cancer. - 1097-0142. ; 73:Suppl. 3, s. 981-984
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND. High resolution spatial details of the distribution of activity in three dimensions is required to evaluate the localization and dosimetric properties of radiolabelled monoclonal antibodies in tumors and normal tissues. Planar imaging of small animals with a resolution of 5-10 mm is usually the imaging modality of choice. The authors investigated high resolution single-photon emission computed tomographic (SPECT) imaging, based on a rotating pinhole scintillation camera. Although the sensitivity of the pinhole collimator is low, several radionuclides offer suitable decay properties to perform pinhole SPECT, especially in conjunction with high activity levels used in radioimmunotherapy. METHODS. Transverse, sagittal, and coronal sections were reconstructed using a three-dimensional cone-beam algorithm, which is a generalization of the two-dimensional fan-beam filtered backprojection algorithm. Before reconstruction, the pinhole projections were corrected for the decay of the radionuclide, geometric and intrinsic efficiency variations of the camera system, and center of rotation shift. RESULTS. The spatial resolution at 50 mm from the pinhole collimator with 3.3 mm aperture was 3.4 mm, and the sensitivity 7.2 c/s microCi for technetium-99m. With the 2 mm collimator the resolution was 2.2 mm, and the sensitivity was 2.6 c/s/microCi. To show the spatial resolution in vivo, a rat was injected with 185 MBq of technetium-99m-methylene diphosphonate or with 5 mCi technetium-99m-hexamethylpropylene amine oxime. The bone structures were well delineated in the methylene diphosphonate image, and in the hexamethylpropylene amine oxime image, the brain was nicely shown. For comparison a magnetic resonance image for the same section was done. CONCLUSIONS. High resolution SPECT imaging with the pinhole collimator provides mapping of the activity in three-dimensions, needed for more detailed biodistribution data and to perform more accurate dosimetry.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Keyword

single-photon emission computed tomography
scintillation camera
pinhole collimator
cone-beam tomography
pinhole single-photon emission computed tomography
high resolution
radionuclides
methylene diphosphonate
hexamethylpropylene amine oxime
monoclonal antibodies

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

  • Cancer (Search for host publication in LIBRIS)

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view