Sökning: (id:"swepub:oai:DiVA.org:kth-266536") >
First experiences o...
First experiences of a low-dose protocol for CT-guided musculoskeletal biopsies combining different radiation dose reduction techniques
-
- Alagic, Zlatan (författare)
- Karolinska Institutet
-
- Alagic, Haris (författare)
- Karolinska Inst, Inst Mol Med & Surg MMK, Diagnost Radiol, Stockholm, Sweden.
-
- Bujila, Robert (författare)
- KTH,Medicinsk bildfysik
-
visa fler...
-
- Srivastava, Subhash (författare)
- Karolinska Univ Hosp, Funct Unit Musculoskeletal Radiol Funct Imaging &, S-17176 Stockholm, Sweden.
-
- Jasim, Saif (författare)
- Karolinska Univ Hosp, Funct Unit Musculoskeletal Radiol Funct Imaging &, S-17176 Stockholm, Sweden.
-
- Lindqvist, Maria (författare)
- Karolinska Univ Hosp, Funct Unit Musculoskeletal Radiol Funct Imaging &, S-17176 Stockholm, Sweden.
-
- Wick, Marius C. (författare)
- Karolinska Univ Hosp, Funct Unit Musculoskeletal Radiol Funct Imaging &, S-17176 Stockholm, Sweden.;Karolinska Inst, Inst Mol Med & Surg MMK, Diagnost Radiol, Stockholm, Sweden.
-
visa färre...
-
Karolinska Institutet Karolinska Inst, Inst Mol Med & Surg MMK, Diagnost Radiol, Stockholm, Sweden (creator_code:org_t)
- 2019-05-15
- 2020
- Engelska.
-
Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 61:1, s. 28-36
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background The use of computed tomography (CT) for image guidance during biopsies is a powerful approach. The method is, however, often associated with a significant level of radiation exposure to the patient and operator. Purpose To investigate if a low-dose protocol for CT-guided musculoskeletal (MSK) biopsies, including a combination of different radiation dose (RD) techniques, is feasible in a clinical setting. Material and Methods Fifty-seven patients underwent CT-guided fine-needle aspiration cytology (FNAC) utilizing the low-dose protocol (group A). A similar number of patients underwent CT-guided FNAC using the reference protocol (group B). Between-group comparisons comprised radiation dose, success rate, image quality parameters, and workflow. Results In group A, the mean total dose-length product (DLP) was 41.2 +/- 2.9 mGy*cm, which was statistically significantly lower than of group B (257.4 +/- 22.0 mGy*cm), corresponding to a mean dose reduction of 84% (P<0.001). The mean CTDIvol for the control scans were 1.88 +/- 0.09 mGy and 13.16 +/- 0.40 mGy for groups A and B, respectively (P < 0.001). The success rate in group A was 91.2% and 87.9% in group B (P = 0.56). No negative effect on image-quality parameters, time of FNAC, and number of control scans were found. Conclusion We successfully developed a low-dose protocol for CT-guided MSK biopsies that maintains diagnostic accuracy and image quality at a fraction of the RD compared to the reference biopsy protocol at our clinic.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- Image-guided biopsy
- interventional radiology
- multidetector computed tomography
- musculoskeletal system
- radiation dosage
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas