SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0003 2670 OR L773:1873 4324
 

Sökning: L773:0003 2670 OR L773:1873 4324 > (1984) > Determination of am...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00002475naa a2200313 4500
001oai:DiVA.org:liu-88167
003SwePub
008130130s1984 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-881672 URI
024a https://doi.org/10.1016/S0003-2670(00)85624-X2 DOI
040 a (SwePub)liu
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Winquist, Fredriku Linköpings universitet,Tillämpad Fysik,Tekniska högskolan4 aut0 (Swepub:liu)frewi90
2451 0a Determination of ammonia in air and aqueous samples with a gas-sensitive semiconductor capacitor
264 1b Elsevier,c 1984
338 a print2 rdacarrier
520 a The properties of a new type of ammonia gas-sensitive semiconductor capacitor are described. The sensor is based on a palladium MOS field-effect capacitor with a thin layer (3 nm) of iridium surrounding the palladium gate. The lower limit of detection for ammonia in air is 1 ppm (0.59 mg kg−1). The analytical characteristics and temperature-dependence of the sensor in measurements of ammonia in air are evaluated. Ammonia in aqueous solutions is determined by the use of a continuous flow system utilizing a gaspermeable membrane in combination with the sensor. The calibration plot of the voltage drop of the capacitor vs. ammonia concentration in 150-μl samples is linear in the concentration range 0.2 × 10−6–5 × 10−5 M. Ammonia is determined in rain and river water as well as in whole blood and blood serum; 15 samples per hour can be assayed. Analytical recovery studies and the selectivity properties of the system are described and discussed. Finally, the properties of the flow-through system in continuous monitoring are described.
653 a TECHNOLOGY
653 a TEKNIKVETENSKAP
700a Spetz, Anitau Linköpings universitet,Tillämpad Fysik,Tekniska högskolan4 aut0 (Swepub:liu)anill63
700a Lundström, Ingemaru Linköpings universitet,Tillämpad Fysik,Tekniska högskolan4 aut0 (Swepub:liu)inglu57
700a Danielsson, B.u University of Lund, Sweden4 aut
710a Linköpings universitetb Tillämpad Fysik4 org
773t Analytica Chimica Actad : Elsevierg 164, s. 127-138q 164<127-138x 0003-2670x 1873-4324
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-88167
8564 8u https://doi.org/10.1016/S0003-2670(00)85624-X

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy