SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

L773:0094 2405 OR L773:2473 4209
 

Sökning: L773:0094 2405 OR L773:2473 4209 > (1990-1994) > Linköpings universitet > Microbeam Radiation...

Microbeam Radiation Therapy

Slatkin, Daniel (författare)
Brookhaven National Laboratory
Spanne, Per (författare)
Brookhaven National Laboratory
Dilmanian, Avraham (författare)
Brookhaven National Laboratory
visa fler...
Sandborg, Michael, 1961- (författare)
Östergötlands Läns Landsting,Linköpings universitet,Medicinsk radiofysik,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Radiofysikavdelningen
visa färre...
 (creator_code:org_t)
1998-06-04
1992
Engelska.
Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 19, s. 1395-1400
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • It is proposed to carry out radiotherapy and radiosurgery for brain lesions by crossfiring an array of parallel, closely spaced microbeams of synchrotron-generated x rays several times through an isocentric target, each microbeam in the array having an 25-µm-wide adjustable-height rectangular cross section. The following inferences from the known tissue sparing of 22-MeV deuteron microbeams in the mouse brain and the following exemplary Monte Carlo computations indicate that endothelial cells in the brain that are lethally irradiated by any microbeam in an array of adequately spaced microbeams outside an isocentric target will be replaced by endothelial cells regenerated from microscopically contiguous, minimally irradiated endothelium in intermicrobeam segments of brain vasculature. Endothelial regeneration will prevent necrosis of the nontargeted parenchymal tissue. However, neoplastic and/or nonneoplastic targeted tissues at the isocenter will be so severely depleted of potentially mitotic endothelial and parenchymal cells by multiple overlapping microbeams that necrosis will ensue. The Monte Carlo computations simulate microbeam irradiations of a 16-cm diameter, 16-cm-long cylindrical human head phantom using 50-, 100-, and 150-keV monochromatic x rays.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy