Search: WFRF:(Ahnesjö Anders Professor)
> (2010-2014) >
Ion recombination i...
Ion recombination in liquid ionization chambers : development of an experimental method to quantify general recombination
-
- Andersson, Jonas, 1975- (author)
- Umeå universitet,Radiofysik
-
- Tölli, Heikki, Filosofie doktor (thesis advisor)
- Umeå universitet,Radiofysik
-
Johansson, Lennart (thesis advisor)
-
show more...
-
- Ahnesjö, Anders, Professor (opponent)
- Uppsala universitet
-
show less...
-
(creator_code:org_t)
- ISBN 9789174596076
- Umeå : Umeå universitet, 2013
- English 76 s.
-
Series: Umeå University medical dissertations, 0346-6612 ; 1567
- Related links:
-
https://umu.diva-por...
-
show more...
-
https://umu.diva-por...
-
https://umu.diva-por... (primary) (Raw object)
-
https://urn.kb.se/re...
-
show less...
Abstract
Subject headings
Close
- An experimental method (the two-dose-rate method) for the correction of general recombination losses in liquid ionization chambers has been developed and employed in experiments with different liquids and radiation qualities. The method is based on a disassociation of initial and general recombination, since an ionized liquid is simultaneously affected by both of these processes.The two-dose-rate method has been compared to an existing method for general recombination correction for liquid ionization chambers, and has been found to be the most robust method presently available.The soundness of modelling general recombination in liquids on existing theory for gases has been evaluated, and experiments indicate that the process of general recombination is similar in a gas and a liquid. It is thus reasonable to employ theory for gases in the two-dose-rate method to achieve experimental corrections for general recombination in liquids. There are uncertainties in the disassociation of initial and general recombination in the two-dose-rate method for low applied voltages, where initial recombination has been found to cause deviating results for different liquids and radiation qualities.Sensitivity to ambient electric fields has been identified in the microLion liquid ionization chamber (PTW, Germany). Experimental data may thus be perturbed if measurements are conducted in the presence of ambient electric fields, and the sensitivity has been found to increase with an increase in the applied voltage. This can prove to be experimentally limiting since general recombination may be too severe for accurate corrections if the applied voltage is low.
Subject headings
- NATURVETENSKAP -- Fysik -- Annan fysik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Other Physics Topics (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Keyword
- General recombination
- initial recombination
- liquid ionization chamber
- radiation dosimetry
- radiofysik
- radiation physics
Publication and Content Type
- vet (subject category)
- dok (subject category)
Find in a library
To the university's database