Femoral alignment of the Charnley stem: a randomized trial comparing the original with the new instrumentation in 123 hips.
-
- Östgaard, Hans-Christian, 1948 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
-
- Helger, Lilliane, 1957 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
-
- Regnér, Hans, 1923 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
-
visa fler...
-
- Garellick, Göran, 1948 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
-
visa färre...
-
(creator_code:org_t)
- 2009-07-08
- 2001
- Engelska.
-
Ingår i: Acta orthopaedica Scandinavica. - : Medical Journals Sweden AB. - 0001-6470. ; 72:3, s. 228-32
- Relaterad länk:
-
https://www.tandfonl...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Deficient cement mantles are associated with aseptic loosening of the stem component of total hip replacement. In a former study of 206 Charnley stems, we found high frequencies of stem malalignment, especially on the lateral view, consequently resulting in a high percentage of low cement mantle grading. If the "true" lateral radiographic projection is not used, there is a risk that the frequency of mantle defects is underestimated. A logistic regression analysis showed a high correlation between low cement mantle grading and stem loosening after a mean follow-up of 10 years. The new Charnley instrumentation was introduced in 1994 and we started a randomized trial including 123 prostheses to determine whether the new instrumentation improved the position of the stem in both the AP and lateral planes. Postoperative radiographs revealed a significant change in AP positioning-i.e., from a high percentage of varus with the original method to valgus with the new instrumentation. However, there was no difference on the lateral view, with a persisting high frequency of stems with implant-inner cortex contact resulting in high percentages of low cement-mantle grading in both systems. If this deficiency, in a long-term perspective, is associated with aseptic loosening, as many authors have claimed, the manufacturers should address the problem.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kirurgi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Surgery (hsv//eng)
Nyckelord
- Aged
- Aged
- 80 and over
- Arthroplasty
- Replacement
- Hip
- instrumentation
- Female
- Follow-Up Studies
- Hip
- radiography
- Humans
- Male
- Middle Aged
- Postoperative Complications
- Regression Analysis
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas