Specific detection of L-glutamate in food using flow-injection analysis and enzymatic recycling of substrate

Khampha, Wanida (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Yakovleva, Julia (författare)
Lund University,Lunds universitet,Muskelbiologi,Forskargrupper vid Lunds universitet,Muscle Biology,Lund University Research Groups
Isarangkul, D (författare)
visa fler...
Wiyakrutta, S (författare)
Meevootisom, V (författare)
Emnéus, Jenny (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
Elsevier BV, 2004
2004
Engelska.
Ingår i: Analytica Chimica Acta. - : Elsevier BV. - 1873-4324 .- 0003-2670. ; 518:1-2, s. 127-135
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A flow injection analysis (FIA) system for specific determination of L-glutamate in food samples based on a bi-enzymatic amplification system has been developed. The content of L-glutamate in the sample was amplified by cycling between L-glutamate dehydrogenase (GIDH) and a novel enzyme, D-phenylglycine aminotransferase (D-PhgAT). In this system, GIDH converts L-glutamate to 2-oxoglutarate with concomitant reduction of NAD(+) to NADH. D-PhgAT transfers an amino group from D-4-hydroxyphenylglycine to 2-oxoglutarate, thus recycling L-glutamate. Accumulation of NADH in the course of the enzymatic recycling was monitored both by fluorescence and UV absorbance and used for quantification of L-glutamate. The assay was characterized by high long-term stability (at least 70 days) and good reproducibility (within-day and between-day RSDs were 4.3-7.3% and 8.9%). The fluorimetric assay was slightly more sensitive with a L-glutamate detection limit of 0.4 muM and linear range of 2.5-50 muM. The assay was specific for L-glutamate, with recoveries between 95-103% in the presence of 17 different amino acids tested one by one. The method was applied to analysis of real food samples and results were correlated with a commercial Boehringer Mannheim assay kit. (C) 2004 Elsevier B.V. All rights reserved.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy