Sökning: WFRF:(Larsson Rolf)
> (2005-2009) >
Effects on blood co...
Effects on blood compatibility in vitro by combining a direct P2Y(12) receptor inhibitor and heparin coating of stents
-
- Christensen, Kjeld (författare)
- Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
-
- Larsson, Rolf (författare)
- Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
-
Emanuelsson, Håkan (författare)
-
visa fler...
-
- Elgue, Graciela (författare)
- Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
-
- Larsson, Anders (författare)
- Uppsala universitet,Institutionen för medicinska vetenskaper,Biokemisk struktur och funktion
-
visa färre...
-
(creator_code:org_t)
- 2009-07-07
- 2006
- Engelska.
-
Ingår i: Platelets. - : Informa UK Limited. - 0953-7104 .- 1369-1635. ; 17:5, s. 318-327
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The effect of the direct platelet P2Y12 receptor inhibitor, AR-C69931MX, on activation of blood induced by stents with and without heparin coating was investigated using a whole blood Chandler loop model in vitro . Stents were deployed in Chandler loops. Fresh human blood with heparin and AR-C69931MX was rotated for 1 h at 37°C and used for measurements of platelets, microparticles, thrombin-antithrombin complex (TAT), fibrinogen binding to platelets, P-selectin expression by platelets, CD11b, Prothrombin Fragment F1+2, FXIa-AT, FXIIa-AT, C3a, sC5b-9 and stent score. In the first experiment there were four study groups with unmodified stents: 1a, no AR-C69931MX; 1b, 250 nmol/L; 1c, 750 nmol/L; 1d, 2250 nmol/L of AR-C69931MX. In the second experiment the concentration of AR-C69931MX was 500 nmol/L: 2a; tubings without stent; 2b; tubings with heparin-coated stent; 2c; tubings with unmodified stents. Heparin-coated stents were used in the third experiment: 3a; no AR-C69931MX; 3b; 500 nmol/L of AR-C69931MX. In the first experiment there were significant differences in all parameters analysed except for C3a, and stent score when the group with no AR-C69931MX was compared to all the groups with AR-C69931MX. In the second experiment there were significant differences in platelet count, TAT, FXIa-AT, FXIIa-AT and stent score when unmodified stents were compared to loops with no stents and partly to loops with heparin-coated stents. In the third experiment there was a significant reduction in generation of TAT, stent score and better preservation of platelet number by combining the platelet inhibitor and heparin-coated stents as compared to heparin-coated stents alone. The conclusion is that the direct P2Y12 receptor inhibitor AR-C69931MX reduced the different aspects of activation of blood induced by both unmodified and heparin-coated stents.
Nyckelord
- Heparin coating
- Platelets
- Purin receptor blockade
- Stents
- MEDICINE
- MEDICIN
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas