SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ninerola Baizan A.)
 

Sökning: WFRF:(Ninerola Baizan A.) > Centiloid cut-off v...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00005746naa a2200973 4500
001oai:gup.ub.gu.se/279667
003SwePub
008240528s2019 | |||||||||||000 ||eng|
024a https://gup.ub.gu.se/publication/2796672 URI
024a https://doi.org/10.1186/s13195-019-0478-z2 DOI
040 a (SwePub)gu
041 a eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Salvado, G.4 aut
2451 0a Centiloid cut-off values for optimal agreement between PET and CSF core AD biomarkers
264 c 2019-03-21
264 1b Springer Science and Business Media LLC,c 2019
520 a BackgroundThe Centiloid scale has been developed to standardize measurements of amyloid PET imaging. Reference cut-off values of this continuous measurement enable the consistent operationalization of decision-making for multicentre research studies and clinical trials. In this study, we aimed at deriving reference Centiloid thresholds that maximize the agreement against core Alzheimer's disease (AD) cerebrospinal fluid (CSF) biomarkers in two large independent cohorts.MethodsA total of 516 participants of the ALFA+ Study (N=205) and ADNI (N=311) underwent amyloid PET imaging ([F-18]flutemetamol and [F-18]florbetapir, respectively) and core AD CSF biomarker determination using Elecsys (R) tests. Tracer uptake was quantified in Centiloid units (CL). Optimal Centiloid cut-offs were sought that maximize the agreement between PET and dichotomous determinations based on CSF levels of A(42), tTau, pTau, and their ratios, using pre-established reference cut-off values. To this end, a receiver operating characteristic analysis (ROC) was conducted, and Centiloid cut-offs were calculated as those that maximized the Youden's J Index or the overall percentage agreement recorded.ResultsAll Centiloid cut-offs fell within the range of 25-35, except for CSF A(42) that rendered an optimal cut-off value of 12 CL. As expected, the agreement of tau/A(42) ratios was higher than that of CSF A(42). Centiloid cut-off robustness was confirmed even when established in an independent cohort and against variations of CSF cut-offs.ConclusionsA cut-off of 12 CL matches previously reported values derived against postmortem measures of AD neuropathology. Together with these previous findings, our results flag two relevant inflection points that would serve as boundary of different stages of amyloid pathology: one around 12 CL that marks the transition from the absence of pathology to subtle pathology and another one around 30 CL indicating the presence of established pathology. The derivation of robust and generalizable cut-offs for core AD biomarkers requires cohorts with adequate representation of intermediate levels.Trial registrationALFA+ Study, NCT02485730ALFA PET Sub-study, NCT02685969
650 7a MEDICIN OCH HÄLSOVETENSKAPx Medicinska och farmaceutiska grundvetenskaperx Neurovetenskaper0 (SwePub)301052 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Basic Medicinex Neurosciences0 (SwePub)301052 hsv//eng
653 a AD pathophysiology
653 a Biomarker concordance
653 a Threshold
653 a Positivity
653 a Preclinical
653 a Early detection
653 a Positron emission tomography
653 a Phosphorylated tau
653 a Biomarker categorization
653 a preclinical alzheimers-disease
653 a beta-amyloid 42
653 a cerebrospinal-fluid
653 a association
653 a prevention
653 a deposition
653 a diagnosis
653 a accuracy
653 a Neurosciences & Neurology
700a Molinuevo, J. L.4 aut
700a Brugulat-Serrat, A.4 aut
700a Falcon, C.4 aut
700a Grau-Rivera, O.4 aut
700a Suarez-Calvet, M.4 aut
700a Pavia, J.4 aut
700a Ninerola-Baizan, A.4 aut
700a Perissinotti, A.4 aut
700a Lomena, F.4 aut
700a Minguillon, C.4 aut
700a Fauria, K.4 aut
700a Zetterberg, Henrik,d 1973u Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi,Institute of Neuroscience and Physiology4 aut0 (Swepub:gu)xzethe
700a Blennow, Kaj,d 1958u Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi,Institute of Neuroscience and Physiology4 aut0 (Swepub:gu)xbleka
700a Gispert, J. D.4 aut
700a Cami, J.4 aut
700a Cacciaglia, R.4 aut
700a Crous-Bou, M.4 aut
700a Deulofeu, C.4 aut
700a Dominguez, R.4 aut
700a Gotsens, X.4 aut
700a Gramunt, N.4 aut
700a Hernandez, L.4 aut
700a Huesa, G.4 aut
700a Huguet, J.4 aut
700a Leon, M.4 aut
700a Marne, P.4 aut
700a Menchon, T.4 aut
700a Mila, M.4 aut
700a Operto, G.4 aut
700a Pascual, M.4 aut
700a Polo, A.4 aut
700a Pradas, S.4 aut
700a Sala-Vila, A.4 aut
700a Sanchez-Benavides, G.4 aut
700a Segundo, S.4 aut
700a Soteras, A.4 aut
700a Tenas, L.4 aut
700a Vilanova, M.4 aut
700a Vilor-Tejedor, N.4 aut
710a Göteborgs universitetb Institutionen för neurovetenskap och fysiologi4 org
773t Alzheimers Research & Therapyd : Springer Science and Business Media LLCg 11q 11x 1758-9193
856u https://alzres.biomedcentral.com/track/pdf/10.1186/s13195-019-0478-z
8564 8u https://gup.ub.gu.se/publication/279667
8564 8u https://doi.org/10.1186/s13195-019-0478-z

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy