SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Rosenzweig Ivana)
 

Sökning: WFRF:(Rosenzweig Ivana) > (2013) > Source localization...

  • Beniczky, Sandor (författare)

Source localization of rhythmic ictal EEG activity: A study of diagnostic accuracy following STARD criteria

  • Artikel/kapitelEngelska2013

Förlag, utgivningsår, omfång ...

  • 2013-08-14
  • Wiley,2013

Nummerbeteckningar

  • LIBRIS-ID:oai:lup.lub.lu.se:d5e0e0a1-10e5-4c57-86ec-89a3338020cc
  • https://lup.lub.lu.se/record/4171995URI
  • https://doi.org/10.1111/epi.12339DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • PurposeAlthough precise identification of the seizure-onset zone is an essential element of presurgical evaluation, source localization of ictal electroencephalography (EEG) signals has received little attention. The aim of our study was to estimate the accuracy of source localization of rhythmic ictal EEG activity using a distributed source model. MethodsSource localization of rhythmic ictal scalp EEG activity was performed in 42 consecutive cases fulfilling inclusion criteria. The study was designed according to recommendations for studies on diagnostic accuracy (STARD). The initial ictal EEG signals were selected using a standardized method, based on frequency analysis and voltage distribution of the ictal activity. A distributed source modellocal autoregressive average (LAURA)was used for the source localization. Sensitivity, specificity, and measurement of agreement (kappa) were determined based on the reference standardthe consensus conclusion of the multidisciplinary epilepsy surgery team. Predictive values were calculated from the surgical outcome of the operated patients. To estimate the clinical value of the ictal source analysis, we compared the likelihood ratios of concordant and discordant results. Source localization was performed blinded to the clinical data, and before the surgical decision. Key FindingsReference standard was available for 33 patients. The ictal source localization had a sensitivity of 70% and a specificity of 76%. The mean measurement of agreement (kappa) was 0.61, corresponding to substantial agreement (95% confidence interval (CI) 0.38-0.84). Twenty patients underwent resective surgery. The positive predictive value (PPV) for seizure freedom was 92% and the negative predictive value (NPV) was 43%. The likelihood ratio was nine times higher for the concordant results, as compared with the discordant ones. SignificanceSource localization of rhythmic ictal activity using a distributed source model (LAURA) for the ictal EEG signals selected with a standardized method is feasible in clinical practice and has a good diagnostic accuracy. Our findings encourage clinical neurophysiologists assessing ictal EEGs to include this method in their armamentarium.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Lantz, Goran (författare)
  • Rosenzweig, Ivana (författare)
  • Åkeson, PerLund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups(Swepub:lu)ront-pak (författare)
  • Pedersen, Birthe (författare)
  • Pinborg, Lars H. (författare)
  • Ziebell, Morten (författare)
  • Jespersen, Bo (författare)
  • Fuglsang-Frederiksen, Anders (författare)
  • Diagnostisk radiologi, MalmöForskargrupper vid Lunds universitet (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Epilepsia: Wiley54:10, s. 1743-17520013-9580

Internetlänk

Hitta via bibliotek

  • Epilepsia (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng