245 | 1 0 | a Scatter and crosstalk corrections for (99m)Tc/(123)I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators. |
264 | c 2015-11-11 | |
264 | 1 | b Wiley,c 2015 |
520 | a The energy spectrum for a cadmium zinc telluride (CZT) detector has a low energy tail due to incomplete charge collection and intercrystal scattering. Due to these solid-state detector effects, scatter would be overestimated if the conventional triple-energy window (TEW) method is used for scatter and crosstalk corrections in CZT-based imaging systems. The objective of this work is to develop a scatter and crosstalk correction method for (99m)Tc/(123)I dual-radionuclide imaging for a CZT-based dedicated cardiac SPECT system with pinhole collimators (GE Discovery NM 530c/570c). | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng |
700 | 1 | a Hutton, Brian F4 aut |
700 | 1 | a Holstensson, Mariau Karolinska Institutet4 aut |
700 | 1 | a Ljungberg, Michaelu Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine4 aut0 (Swepub:lu)rafy-mlj |
700 | 1 | a Hendrik Pretorius, P4 aut |
700 | 1 | a Prasad, Rameshwar4 aut |
700 | 1 | a Ma, Tianyu4 aut |
700 | 1 | a Liu, Yaqiang4 aut |
700 | 1 | a Wang, Shi4 aut |
700 | 1 | a Thorn, Stephanie L4 aut |
700 | 1 | a Stacy, Mitchel R4 aut |
700 | 1 | a Sinusas, Albert J4 aut |
700 | 1 | a Liu, Chi4 aut |
710 | 2 | a Karolinska Institutetb Medicinsk strålningsfysik, Lund4 org |
773 | 0 | t Medical Physicsd : Wileyg 42:12, s. 6895-6911q 42:12<6895-6911x 0094-2405x 2473-4209 |
856 | 4 | u http://www.ncbi.nlm.nih.gov/pubmed/26632046?dopt=Abstracty FULLTEXT |
856 | 4 | u http://dx.doi.org/10.1118/1.4934830y FULLTEXT |
856 | 4 8 | u https://lup.lub.lu.se/record/8505702 |
856 | 4 8 | u https://doi.org/10.1118/1.4934830 |
856 | 4 8 | u http://kipublications.ki.se/Default.aspx?queryparsed=id:132786324 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy