245 | 1 0 | a Synthetic MRI of the brain in a clinical setting |
264 | c 2012-12 | |
264 | 1 | b Sage Publications,c 2012 |
338 | a electronic2 rdacarrier | |
520 | a BACKGROUND:Conventional magnetic resonance imaging (MRI) has relatively long scan times for routine examinations, and the signal intensity of the images is related to the specific MR scanner settings. Due to scanner imperfections and automatic optimizations, it is impossible to compare images in terms of absolute image intensity. Synthetic MRI, a method to generate conventional images based on MR quantification, potentially both decreases examination time and enables quantitative measurements.PURPOSE:To evaluate synthetic MRI of the brain in a clinical setting by assessment of the contrast, the contrast-to-noise ratio (CNR), and the diagnostic quality compared with conventional MR images.MATERIAL AND METHODS:Twenty-two patients had synthetic imaging added to their clinical MR examination. In each patient, 12 regions of interest were placed in the brain images to measure contrast and CNR. Furthermore, general image quality, probable diagnosis, and lesion conspicuity were investigated.RESULTS:Synthetic T1-weighted turbo spin echo and T2-weighted turbo spin echo images had higher contrast but also a higher level of noise, resulting in a similar CNR compared with conventional images. Synthetic T2-weighted FLAIR images had lower contrast and a higher level of noise, which led to a lower CNR. Synthetic images were generally assessed to be of inferior image quality, but agreed with the clinical diagnosis to the same extent as the conventional images. Lesion conspicuity was higher in the synthetic T1-weighted images, which also had a better agreement with the clinical diagnoses than the conventional T1-weighted images.CONCLUSION:Synthetic MR can potentially shorten the MR examination time. Even though the image quality is perceived to be inferior, synthetic images agreed with the clinical diagnosis to the same extent as the conventional images in this study. | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng |
653 | a CNS | |
653 | a MR imaging | |
653 | a brain | |
653 | a technology assessment | |
653 | a imaging sequences | |
653 | a MEDICINE | |
653 | a MEDICIN | |
700 | 1 | a Warntjes, Jan Bertus Marcelu Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken US4 aut0 (Swepub:liu)marwa64 |
700 | 1 | a Smedby, Örjanu Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Röntgenkliniken i Linköping4 aut0 (Swepub:liu)orjsm14 |
700 | 1 | a Landtblom, Anne-Marieu Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Neurologi,Hälsouniversitetet,Neurologiska kliniken4 aut0 (Swepub:liu)annla55 |
700 | 1 | a Lundberg, Peteru Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiofysik,Hälsouniversitetet,Radiofysikavdelningen US4 aut0 (Swepub:liu)petlu11 |
700 | 1 | a Larsson, Elna-Marieu Uppsala universitet,Enheten för radiologi,Uppsala University, Sweden4 aut0 (Swepub:uu)elnla305 |
700 | 1 | a Warntjes, Jbm4 aut |
710 | 2 | a Linköpings universitetb Centrum för medicinsk bildvetenskap och visualisering, CMIV4 org |
773 | 0 | t Acta Radiologicad : Sage Publicationsg 53:10, s. 1158-1163q 53:10<1158-1163x 0284-1851x 1600-0455 |
856 | 4 | u https://liu.diva-portal.org/smash/get/diva2:608602/FULLTEXT01.pdfx primaryx Raw objecty fulltext:postprint |
856 | 4 | u http://liu.diva-portal.org/smash/get/diva2:608602/FULLTEXT01 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-89641 |
856 | 4 8 | u https://doi.org/10.1258/ar.2012.120195 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-183798 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.