Removing respiratory artefacts from transthoracic bioimpedance spectroscopy measurements

Cuba-Gyllensten, Illapha (author)
KTH,Skolan för teknik och hälsa (STH),Philips Research Europe, High Tech. Campus 34, 5656AE, Eindhoven, Netherlands; ACTLab., Signal Processing Systems, TU Eindhoven, 5600MB Eindhoven, Netherlands
Abtahi, Farhad (author)
Philips Research Europe, High Tech. Campus 34, 5656AE, Eindhoven, Netherlands
Bonomi, Alberto Giovanni. (author)
KTH,Skolan för teknik och hälsa (STH)
show more...
Lindecrantz, Kaj (author)
KTH,Medicinska sensorer, signaler och system,University of Borås, Sweden
Seoane, Fernando (author)
KTH,Medicinska sensorer, signaler och system,Karolinska Institute, Sweden
Amft, O. (author)
ACTLab., Signal Processing Systems, TU Eindhoven, 5600MB Eindhoven, Netherlands
show less...
 (creator_code:org_t)
2013-04-18
2013
English.
In: XV International Conference on Electrical Bio-Impedance (ICEBI) & XIV Conference on Electrical Impedance Tomography (EIT). - : Institute of Physics Publishing (IOPP).
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • Transthoracic impedance spectroscopy (TIS) measurements from wearable textile electrodes provide a tool to remotely and non-invasively monitor patient health. However, breathing and cardiac processes inevitably affect TIS measurements, since they are sensitive to changes in geometry and air or fluid volumes in the thorax. This study aimed at investigating the effect of respiration on Cole parameters extracted from TIS measurements and developing a method to suppress artifacts. TIS data were collected from 10 participants at 16 frequencies (range: 10 kHz - 1 MHz) using a textile electrode system (Philips Technologie Gmbh). Simultaneously, breathing volumes and frequency were logged using an electronic spirometer augmented with data from a breathing belt. The effect of respiration on TIS measurements was studied at paced (10 and 16 bpm) deep and shallow breathing. These measurements were repeated for each subject in three different postures (lying down, reclining and sitting). Cole parameter estimation was improved by assessing the tidal expiration point thus removing breathing artifacts. This leads to lower intra-subject variability between sessions and a need for less measurements points to accurately assess the spectra. Future work should explore algorithmic artifacts compensation models using breathing and posture or patient contextual information to improve ambulatory transthoracic impedance measurements.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Keyword

Air
Artificial intelligence
Electric impedance
Electric impedance tomography
Parameter estimation
Patient monitoring
Textiles

Publication and Content Type

ref (subject category)
kon (subject category)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Cuba-Gyllensten, ...
Abtahi, Farhad
Bonomi, Alberto ...
Lindecrantz, Kaj
Seoane, Fernando
Amft, O.
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Other Medical En ...
Articles in the publication
By the university
Royal Institute of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view