SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:kth-157573"
 

Search: id:"swepub:oai:DiVA.org:kth-157573" > Point-of-Care Verti...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Point-of-Care Vertical Flow Allergen Microarray Assay : Proof of Concept

Chinnasamy, Thiruppathiraja (author)
KTH,Proteomik och nanobioteknologi,Science for Life Laboratory, SciLifeLab
Segerink, Loes I. (author)
Nystrand, Mats (author)
show more...
Gantelius, Jesper (author)
KTH,Proteomik och nanobioteknologi,Science for Life Laboratory, SciLifeLab
Andersson Svahn, Helene (author)
KTH,Proteomik och nanobioteknologi,Science for Life Laboratory, SciLifeLab
show less...
 (creator_code:org_t)
2014-09-01
2014
English.
In: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 60:9, s. 1209-1216
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND: Sophisticated equipment, lengthy protocols, and skilled operators are required to perform protein microarray-based affinity assays. Consequently, novel tools are needed to bring biomarkers and biomarker panels into clinical use in different settings. Here, we describe a novel paper-based vertical flow microarray (VFM) system with a multiplexing capacity of at least 1480 microspot binding sites, colorimetric readout, high sensitivity, and assay time of < 10 min before imaging and data analysis. METHOD: Affinity binders were deposited on nitrocellulose membranes by conventional microarray printing. Buffers and reagents were applied vertically by use of a flow controlled syringe pump. As a clinical model system, we analyzed 31 precharacterized human serum samples using the array system with 10 allergen components to detect specific IgE reactivities. We detected bound analytes using gold nanoparticle conjugates with assay time of <= 10 min. Microarray images were captured by a consumer-grade flatbed scanner. RESULTS: A sensitivity of 1 ng/mL was demonstrated with the VFM assay with colorimetric readout. The reproducibility (CV) of the system was < 14%. The observed concordance with a clinical assay, Immuno-CAP, was R-2 = 0.89 (n = 31). CONCLUSIONS: In this proof-of-concept study, we demonstrated that the VFM assay, which combines features from protein microarrays and paper-based colorimetric systems, could offer an interesting alternative for future highly multiplexed affinity point-of-care testing.

Subject headings

NATURVETENSKAP  -- Kemi -- Annan kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Other Chemistry Topics (hsv//eng)

Keyword

Allergens
Colorimetry
Gold
Humans
Immunoglobulin E
Metal Nanoparticles
Point-of-Care Systems
Protein Array Analysis
Reproducibility of Results
Sensitivity and Specificity

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view