SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:kth-161964"
 

Search: id:"swepub:oai:DiVA.org:kth-161964" > Energy Calibration ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Energy Calibration of a Silicon-Strip Detector for Photon-Counting Spectral CT by Direct Usage of the X-ray Tube Spectrum

Liu, Xuejin (author)
KTH,Medicinsk bildfysik
Chen, Han (author)
KTH,Medicinsk bildfysik
Bornefalk, Hans (author)
KTH,Medicinsk bildfysik
show more...
Danielsson, Mats (author)
KTH,Medicinsk bildfysik
Karlsson, Staffan (author)
KTH,Medicinsk bildfysik
Persson, Mats (author)
KTH,Medicinsk bildfysik
Xu, Cheng (author)
KTH,Medicinsk bildfysik
Huber, Ben (author)
KTH,Medicinsk bildfysik
show less...
 (creator_code:org_t)
2015
2015
English.
In: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 62:1, s. 68-75
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The variation among energy thresholds in a multibin detector for photon-counting spectral CT can lead to ring artefacts in the reconstructed images. Calibration of the energy thresholds can be used to achieve homogeneous threshold settings or to develop compensation methods to reduce the artefacts. We have developed an energy-calibrationmethod for the different comparator thresholds employed in a photon-counting silicon-strip detector. In our case, this corresponds to specifying the linear relation between the threshold positions in units of mV and the actual deposited photon energies in units of keV. This relation is determined by gain and offset values that differ for different detector channels due to variations in the manufacturing process. Typically, the calibration is accomplished by correlating the peak positions of obtained pulse-height spectra to known photon energies, e. g. with the aid of mono-energetic x rays from synchrotron radiation, radioactive isotopes or fluorescence materials. Instead of mono-energetic x rays, the calibrationmethod presented in this papermakes use of a broad x-ray spectrum provided by commercial x-ray tubes. Gain and offset as the calibration parameters are obtained by a regression analysis that adjusts a simulated spectrum of deposited energies to ameasured pulse-height spectrum. Besides the basic photon interactions such as Rayleigh scattering, Compton scattering and photo-electric absorption, the simulation takes into account the effect of pulse pileup, charge sharing and the electronic noise of the detector channels. We verify the method for different detector channels with the aid of a table-top setup, where we find the uncertainty of the keV-value of a calibrated threshold to be between 0.1 and 0.2 keV.

Subject headings

NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)

Keyword

Calibration
computed tomography
Monte-Carlo simulation
photon-counting
silicon-strip detector
spectral CT

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view