SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:kth-344351"
 

Search: id:"swepub:oai:DiVA.org:kth-344351" > First experimental ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Brunskog, RickardKTH,Medicinsk bildfysik,Karolinska University Hospital, MedTechLabs, BioClinicum, Solna, Sweden (author)

First experimental evaluation of a high-resolution deep silicon photon-counting sensor

  • Article/chapterEnglish2024

Publisher, publication year, extent ...

  • SPIE-Intl Soc Optical Eng,2024
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:kth-344351
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-344351URI
  • https://doi.org/10.1117/1.JMI.11.1.013503DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • QC 20240314
  • Purpose: Current photon-counting computed tomography detectors are limited to a pixel size of around 0.3 to 0.5 mm due to excessive charge sharing degrading the dose efficiency and energy resolution as the pixels become smaller. In this work, we present measurements of a prototype photon-counting detector that leverages the charge sharing to reach a theoretical sub-pixel resolution in the order of 1 μm. The goal of the study is to validate our Monte-Carlo simulation using measurements, enabling further development. Approach: We measure the channel response at the MAX IV Lab, in the DanMAX beamline, with a 35 keV photon beam, and compare the measurements with a 2D Monte Carlo simulation combined with a charge transport model. Only a few channels on the prototype are connected to keep the number of wire bonds low. Results: The measurements agree generally well with the simulations with the beam close to the electrodes but diverge as the beam is moved further away. The induced charge cloud signals also seem to increase linearly as the beam is moved away from the electrodes. Conclusions: The agreement between measurements and simulations indicates that the Monte-Carlo simulation can accurately model the channel response of the detector with the photon interactions close to the electrodes, which indicates that the unconnected electrodes introduce unwanted effects that need to be further explored. With the same Monte-Carlo simulation previously indicating a resolution of around 1 μm with similar geometry, the results are promising that an ultra-high resolution detector is not far in the future.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Persson, Mats,1987-KTH,Medicinsk bildfysik,Karolinska University Hospital, MedTechLabs, BioClinicum, Solna, Sweden(Swepub:kth)u1keei5w (author)
  • Jin, ZihuiKTH,Medicinsk bildfysik(Swepub:kth)u1qt1doi (author)
  • Danielsson, Mats,ProfessorKTH,Medicinsk bildfysik,Karolinska University Hospital, MedTechLabs, BioClinicum, Solna, Sweden(Swepub:kth)u1m3qe0f (author)
  • KTHMedicinsk bildfysik (creator_code:org_t)

Related titles

  • In:Journal of Medical Imaging: SPIE-Intl Soc Optical Eng11:12329-43022329-4310

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view