Sökning: id:"swepub:oai:DiVA.org:liu-179445" >
Mueller matrix imag...
Mueller matrix imaging microscope using dual continuously rotating anisotropic mirrors
-
- Ruder, Alexander (författare)
- Univ Nebraska, NE 68588 USA
-
- Wright, Brandon (författare)
- Univ Nebraska, NE 68588 USA
-
- Feder, Rene (författare)
- Fraunhofer Inst Microstruct Mat & Syst IMWS, Germany
-
visa fler...
-
- Kilic, Ufuk (författare)
- Univ Nebraska, NE 68588 USA
-
- Hilfiker, Matthew (författare)
- Univ Nebraska, NE 68588 USA
-
- Schubert, Eva (författare)
- Univ Nebraska, NE 68588 USA
-
- Herzinger, Craig M. (författare)
- JA Woollam Co Inc, NE 68508 USA
-
- Schubert, Mathias (författare)
- Linköpings universitet,Halvledarmaterial,Tekniska fakulteten,Univ Nebraska, NE 68588 USA; Leibniz Inst Polymer Res eV, Germany
-
visa färre...
-
(creator_code:org_t)
- Optical Society of America, 2021
- 2021
- Engelska.
-
Ingår i: Optics Express. - : Optical Society of America. - 1094-4087. ; 29:18, s. 28704-28724
- Relaterad länk:
-
https://liu.diva-por... (primary) (Raw object)
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- We demonstrate calibration and operation of a Mueller matrix imaging microscope using dual continuously rotating anisotropic mirrors for polarization state generation and analysis. The mirrors contain highly spatially coherent nanostructure slanted columnar titanium thin films deposited onto optically thick titanium layers on quartz substrates. The first mirror acts as polarization state image generator and the second mirror acts as polarization state image detector. The instrument is calibrated using samples consisting of laterally homogeneous properties such as straight-through-air, a clear aperture linear polarizer, and a clear aperture linear retarder waveplate. Mueller matrix images are determined for spatially varying anisotropic samples consisting of a commercially available (Thorlabs) birefringent resolution target and a spatially patterned titanium slanted columnar thin film deposited onto a glass substrate. Calibration and operation are demonstrated at a single wavelength (530 nm) only, while, in principle, the instrument can operate regardless of wavelength. We refer to this imaging ellipsometry configuration as rotating-anisotropic-mirror-sample-rotating-anisotropic-mirror ellipsometry (RAM-S-RAM-E). (C) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
Ämnesord
- NATURVETENSKAP -- Fysik -- Annan fysik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Other Physics Topics (hsv//eng)
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas