Polarized laser Doppler perfusion imaging—reduction of movement-induced artifacts

Karlsson, Daniel M G, 1974- (author)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
Wårdell, Karin, 1959- (author)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,MINT
 (creator_code:org_t)
SPIE - International Society for Optical Engineering, 2005
2005
English.
In: Journal of Biomedical Optics. - : SPIE - International Society for Optical Engineering. - 1083-3668 .- 1560-2281. ; 10:6
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Laser Doppler perfusion imaging (LDPI) enables superficial tissue perfusion assessment, but is sensitive to tissue motion not related to blood cells. The aim was to investigate if a polarization technique could reduce movement-induced artifacts. A linearly polarized laser and a cross-polarized filter, placed in front of the detectors, were used to block specular reflection. Measurements were performed with, and without, the polarization filter, at a single site during horizontal and vertical movement of skin tissue (index finger, twelve subjects, n=112) and of a flow model (n=432), with varying surface structures. Measurements were repeated during different flow conditions and at increased skin specular reflection. Statistical analysis was performed using ANOVA models. The perfusion signal was lower (p<0.001, skin and p<0.05, flow model) using the polarization filter, due to movement artifact reduction. No significant influence from surface structure was found when using the polarization filter. Movement artifacts were lower (p<0.05) in the vertical movement direction, however, depending on flow conditions for skin measurements. Increased skin specular reflection gave rise to large movement artifacts without the polarization filter. In conclusion, the polarized LDPI technique reduces movement artifacts and is particularly appropriate when assessing, e.g., ulcers and burns, where specular reflection is high.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Keyword

MEDICINE
MEDICIN

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Karlsson, Daniel ...
Wårdell, Karin, ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Laborato ...
Articles in the publication
Journal of Biome ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view