100a Arildsson, Mikael,d 1967-u Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan4 aut
2451 0a Critical design parameters in laser Doppler perfusion imaging
264 1b SPIE Proceedings Series,c 1996
338 a print2 rdacarrier
520 a Laser Doppler Perfusion Imaging (LDPI) is a method for visualization of tissue blood perfusion. A low power laser beam is used to step-wise scan a tissue area of interest and a perfusion estimate based on the backscattered, partially Doppler broadened, light is generated. Although the basic operating principle of LDPI is the same as that of conventional Laser Doppler Perfusion Monitoring (LDPM), significant differences exist between the implementation of the methods which must be taken into account in order to generate high quality perfusion images. The purpose of this study is to investigate the relevance of a number of LDPI design parameters, such as:(1) The influence of artifact noise when using a continuously moving laser beam instead of a step-wise moving beam to scan the image.(2) The signal processor output's dependency on the distance between the measurement object and the scanner head when using collimated laser light.(3) The speed and mode of the scanning.The results show a substantial rise in the noise level when using a continuously moving beam as opposed to a step-wise. Skin measurements using a collimated laser beam demonstrated an amplification factor dependency on the distance between the skin surface and the scanner head not present when using a divergent laser beam. The scanning speed is limited by the trade-off between the Doppler signal lower cut-off frequency and the image quality.
653 a MEDICINE
653 a MEDICIN
700a Nilsson, Gert,d 1947-u Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan4 aut0 (Swepub:liu)gerni17
700a Wårdell, Karinu Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan4 aut0 (Swepub:liu)karwa46
710a Linköpings universitetb Institutionen för medicinsk teknik4 org
773t <em>Proc. SPIE</em> 2678d : SPIE Proceedings Seriesg , s. 401-408q <401-408z 9780819420527
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-33211
8564 8u https://doi.org/10.1117/12.239527

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy