SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:ltu-67443"
 

Sökning: id:"swepub:oai:DiVA.org:ltu-67443" > Effect of Working P...

Effect of Working Parameters of the Plate Heat Exchanger on the Thermal Performance of the Anti-Bact Heat Exchanger System to Disinfect Legionella in Hot Water Systems

Altorkmany, Lobna (författare)
Luleå tekniska universitet,Arkitektur och vatten,Luleå tekniska universitet (LTU),Luleå University of Technology (LTU)
Kharseh, Mohamad, 1980 (författare)
Civil Environmental Engineering Department, Chalmers University of Technology, Sweden,Chalmers tekniska högskola,Chalmers University of Technology
Ljung, Anna-Lena (författare)
Luleå tekniska universitet,Strömningslära och experimentell mekanik,Luleå tekniska universitet (LTU),Luleå University of Technology (LTU)
visa fler...
Lundström, Staffan (författare)
Luleå tekniska universitet,Strömningslära och experimentell mekanik,Luleå tekniska universitet (LTU),Luleå University of Technology (LTU)
visa färre...
 (creator_code:org_t)
Elsevier, 2018
2018
Engelska.
Ingår i: Applied Thermal Engineering. - : Elsevier. - 1359-4311 .- 1873-5606. ; 141, s. 435-443
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The objective of the current study is to analyze the effect of different working parameters on the thermal performance of the Anti-Bact Heat Exchanger system (ABHE). The ABHE system is inspired by nature and implemented to achieve continuous disinfection of Legionella in different human-made water systems at any desired disinfection temperature. In the ABHE system, most of the energy is recovered using an efficient plate heat exchanger (PHE). A model by Engineering Equation Solver (EES) is set-up to figure out the effect of different working parameters on the thermal performance of the ABHE system. The study shows that higher supplied water temperature can enhance the regeneration ratio (RR), but it requires a large PHE area and pumping power (PP) which consequently increase the cost of the ABHE system. However, elevate temperature in use results in a reduced PHE area and PP, which accordingly reduce the cost of the ABHE system. On the other hand, the EES-based model is used to study the effect of the length and the width of the plates used in the PHE on the RR and the required area of the PHE. Finally, taking into account the geometrical parameters, flow arrangement and the initial operating conditions of the PHE, the EES-based model is used to optimize the PHE in which its area is minimized, and the RR of the ABHE system is maximized.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Legionella
thermal disinfection
simulation
thermal performance
plate heat exchanger
Strömningslära
Fluid Mechanics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng