Experimental investigation of structural failure during the cooling phase of a fire : Concrete columns

Gernay, Thomas (author)
Johns Hopkins University, USA
Franssen, Jean-Marc (author)
Liege University, Belgium,University of Liège
Robert, Fabienne (author)
CERIB Fire Testing Centre, France,CERIB Fire Testing Centre (CEF)
show more...
McNamee, Robert (author)
Lunds universitet,RISE,Brand och Säkerhet,Lund University, Sweden,Avdelningen för Brandteknik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Fire Safety Engineering,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH,Research Institutes of Sweden (RISE)
Felicetti, Roberto (author)
Politecnico di Milano, Italy,Polytechnic University of Milan
Bamonte, Patrick (author)
Politecnico di Milano, Italy,Polytechnic University of Milan
Brunkhorst, Sven (author)
Technische Universität Braunschweig, Germany,Technical University of Braunschweig
Mohaine, Siyimane (author)
CERIB Fire Testing Centre, France
Zehfuß, Jochen (author)
Technische Universität Braunschweig, Germany,Technical University of Braunschweig
show less...
 (creator_code:org_t)
Elsevier Ltd, 2022
2022
English.
In: Fire safety journal. - : Elsevier Ltd. - 0379-7112 .- 1873-7226. ; 134
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Structures may collapse during the cooling phase of a fire, yet standard furnace tests only measure the response under heating. There lacks experimental test protocols and design methods to assess resistance until burnout. This paper describes a new experimental approach for burnout resistance evaluation, reports experimental data on loaded reinforced concrete columns in furnace tests with cooling down phases, and presents numerical models of the tests. The test results show that columns designed for a standard fire resistance of 60 min exhibited a fire resistance of 83 min in the furnace but failed during the cooling phase when the burners were shut off after 72 min while the load was maintained. Two other specimens survived exposure to heating of 45 and 55 min, respectively, and their residual capacity was measured. Finite element analyses show agreement with the tests, showing applicability of numerical methods for evaluating burnout resistance of concrete columns. These findings demonstrate experimentally that delayed thermal-mechanical effects can jeopardize structural stability in real fires, and provide a framework to measure these effects. Moving beyond fire resistance to quantify the response until burnout will support designs for safety of occupants and firefighters throughout the fire and promote repairability and resilience. 

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering (hsv//eng)

Keyword

Burnout resistance
Concrete columns
Cooling phase
Fire tests
Numerical model
Structural failure
Concrete construction
Cooling
Failure (mechanical)
Fracture mechanics
Furnaces
Numerical methods
Numerical models
Reinforced concrete
Stability
Structural integrity
Concrete column
Experimental investigations
Experimental test
Furnace tests
Test designs
Test protocols
Fire resistance
Burnout resistance
Concrete columns
Cooling phase
Fire tests
Numerical model
Structural failure

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view