Failure of total hip implants : metals and metal release in 52 cases
-
Jakobsen, Stig S. (författare)
-
- Liden, Carola (författare)
- Karolinska Institutet
-
Soballe, Kjeld (författare)
-
visa fler...
-
Johansen, Jeanne D. (författare)
-
Menne, Torkil (författare)
-
- Lundgren, Lennart (författare)
- Stockholms universitet,Institutionen för tillämpad miljövetenskap (ITM),Karolinska Institutet, Sweden
-
Bregnbak, David (författare)
-
Moller, Per (författare)
-
Jellesen, Morten S. (författare)
-
Thyssen, Jacob P. (författare)
-
visa färre...
-
(creator_code:org_t)
- 2014-07-18
- 2014
- Engelska.
-
Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 71:6, s. 319-325
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- BackgroundThe pathogenesis of total joint replacement failure is multifactorial. One hypothesis suggests that corrosion and wear of alloys result in metal ion release, which may then cause sensitization and even implant failure, owing to the acquired immune reactivity. ObjectivesTo assess cobalt, nickel and chromium(VI) release from, and the metal composition of, failed metal-on-ethylene total hip replacements. Materials/methodsImplant components from 52 revision cases were evaluated with spot tests for free nickel, cobalt, and chromium (VI) ions. Implant composition was determined with X-ray fluorescence spectroscopy, and information on the reason for revision and complications in relation to surgery was collected from the medical charts when possible (72%). For 10 implants, corrosion was further characterized with scanning electron microscopy. ResultsWe detected cobalt release from three of 38 removed femoral heads and from one of 24 femoral stems. Nickel release was detected from one of 24 femoral stems. No chromium(VI) release was detected. ConclusionsWe found that cobalt and nickel were released from some failed total hip arthroplasties, and corrosion was frequently observed. Metal ions and particles corroded from metal-on-polyethylene may play a role in the complex aetiopathology of implant failure.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine (hsv//eng)
- NATURVETENSKAP -- Geovetenskap och miljövetenskap -- Miljövetenskap (hsv//swe)
- NATURAL SCIENCES -- Earth and Related Environmental Sciences -- Environmental Sciences (hsv//eng)
Nyckelord
- chromium
- cobalt
- metal allergy
- nickel
- spot test
- total joint replacement
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Jakobsen, Stig S ...
-
Liden, Carola
-
Soballe, Kjeld
-
Johansen, Jeanne ...
-
Menne, Torkil
-
Lundgren, Lennar ...
-
visa fler...
-
Bregnbak, David
-
Moller, Per
-
Jellesen, Morten ...
-
Thyssen, Jacob P ...
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
- NATURVETENSKAP
-
NATURVETENSKAP
-
och Geovetenskap och ...
-
och Miljövetenskap
- Artiklar i publikationen
-
Contact Dermatit ...
- Av lärosätet
-
Stockholms universitet
-
Karolinska Institutet