SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:su-156412"
 

Search: id:"swepub:oai:DiVA.org:su-156412" > Estimation of Risk ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Estimation of Risk of Normal-tissue Toxicity Following Gastric Cancer Radiotherapy with Photon- or Scanned Proton-beams

Mondlane, Gracinda, 1987- (author)
Stockholms universitet,Fysikum,Eduardo Mondlane University, Mozambique
Ureba, Ana (author)
Karolinska Institutet,Stockholms universitet,Fysikum
Gubanski, Michael (author)
Karolinska Institutet
show more...
Lind, Pehr A. (author)
Karolinska Institutet
Siegbahn, Albert (author)
Karolinska Institutet
show less...
 (creator_code:org_t)
Anticancer Research USA Inc. 2018
2018
English.
In: Anticancer Research. - : Anticancer Research USA Inc.. - 0250-7005 .- 1791-7530. ; 38:5, s. 2619-2625
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background/Aim: Gastric cancer (GC) radiotherapy involves irradiation of large tumour volumes located in the proximities of critical structures. The advantageous dose distributions produced by scanned-proton beams could reduce the irradiated volumes of the organs at risk (OARs). However, treatment-induced side-effects may still appear. The aim of this study was to estimate the normal tissue complication probability (NTCP) following proton therapy of GC, compared to photon radiotherapy. Patients and Methods: Eight GC patients, previously treated with volumetric-modulated arc therapy (VMAT), were retrospectively planned with scanned proton beams carried out with the single-field uniform-dose (SFUD) method. A beam-specific planning target volume was used for spot positioning and a clinical target volume (CTV) based robust optimisation was performed considering setup- and range-uncertainties. The dosimetric and NTCP values obtained with the VMAT and SFUD plans were compared. Results: With SFUD, lower or similar dose-volume values were obtained for OARs, compared to VMAT. NTCP values of 0% were determined with the VMAT and SFUD plans for all OARs (p>0.05), except for the left kidney (p<0.05), for which lower toxicity was estimated with SFUD. Conclusion: The NTCP reduction, determined for the left kidney with SFUD, can be of clinical relevance for preserving renal function after radiotherapy of GC.

Subject headings

NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)

Keyword

NTCP
gastric cancer
VMAT
SFUD
treatment planning
Medical Radiation Physics
medicinsk strålningsfysik

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view