Evaluation of applanation resonator sensors for intra-ocular pressure measurement : results from clinical and in vitro studies.

Eklund, Anders (författare)
Umeå universitet,Radiofysik,Umeå University Hospital, Department of Biomedical Engineering & Informatics
Lindén, Christina (författare)
Umeå universitet,Institutionen för klinisk vetenskap,Umeå University, Department of Clinical Science, Ophthalmology
Bäcklund, Tomas (författare)
Umeå universitet,Radiofysik,Umeå University Hospital, Department of Biomedical Engineering & Informatics
visa fler...
Andersson, Britt M, 1962- (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,Centrum för medicinsk teknik och fysik (CMTF),Umeå University. Department of Applied Physics and Electronics
Lindahl, Olof A, 1955- (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,Centrum för medicinsk teknik och fysik (CMTF)
visa färre...
 (creator_code:org_t)
2003
2003
Engelska.
Ingår i: Medical and Biological Engineering and Computing. - 0140-0118 .- 1741-0444. ; 41:2, s. 190-197
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Glaucoma is an eye disease that, in its most common form, is characterised by high intra-ocular pressure (IOP), reduced visual field and optic nerve damage. For diagnostic purposes and for follow-up after treatment, it is important to have simple and reliable methods for measuring IOP. Recently, an applanation resonator sensor (ARS) for measuring IOP was introduced and evaluated using an in vitro pig-eye model. In the present study, the first clinical evaluation of the same probe has been carried out, with experiments in vivo on human eyes. There was a low but significant correlation between IOP(ARS) and the IOP measured with a Goldmann applanation tonometer (r = 0.40, p = 0.001, n = 72). However, off-centre positioning of the sensor against the cornea caused a non-negligible source of error. The sensor probe was redesigned to have a spherical, instead of flat, contact surface against the eye and was evaluated in the in vitro model. The new probe showed reduced sensitivity to off-centre positioning, with a decrease in relative deviation from 89% to 11% (1 mm radius). For normalised data, linear regression between IOP(ARS) and direct IOP measurement in the vitreous chamber showed a correlation of r = 0.97 (p < 0.001, n = 108) and a standard deviation for the residuals of SD < or = 2.18 mm Hg (n = 108). It was concluded that a spherical contact surface should be preferred and that further development towards a clinical instrument should focus on probe design and signal analysis.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Nyckelord

resonance sensor
intra-ocular pressure
Medical engineering
Medicinsk teknik
Ophtalmiatrics
Oftalmiatrik
Ophtalmology
oftalmiatrik
Medical Engineering for Healthcare

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy