2451 0a Evaluation of applanation resonator sensors for intra-ocular pressure measurement :b results from clinical and in vitro studies.
264 1c 2003
338 a print2 rdacarrier
500 a Upprättat; 2003; 20070530 (andbra)
520 a Glaucoma is an eye disease that, in its most common form, is characterised by high intra-ocular pressure (IOP), reduced visual field and optic nerve damage. For diagnostic purposes and for follow-up after treatment, it is important to have simple and reliable methods for measuring IOP. Recently, an applanation resonator sensor (ARS) for measuring IOP was introduced and evaluated using an in vitro pig-eye model. In the present study, the first clinical evaluation of the same probe has been carried out, with experiments in vivo on human eyes. There was a low but significant correlation between IOP(ARS) and the IOP measured with a Goldmann applanation tonometer (r = 0.40, p = 0.001, n = 72). However, off-centre positioning of the sensor against the cornea caused a non-negligible source of error. The sensor probe was redesigned to have a spherical, instead of flat, contact surface against the eye and was evaluated in the in vitro model. The new probe showed reduced sensitivity to off-centre positioning, with a decrease in relative deviation from 89% to 11% (1 mm radius). For normalised data, linear regression between IOP(ARS) and direct IOP measurement in the vitreous chamber showed a correlation of r = 0.97 (p < 0.001, n = 108) and a standard deviation for the residuals of SD < or = 2.18 mm Hg (n = 108). It was concluded that a spherical contact surface should be preferred and that further development towards a clinical instrument should focus on probe design and signal analysis.
650 7a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Medicinsk laboratorie- och mätteknik0 (SwePub)206012 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Medical Laboratory and Measurements Technologies0 (SwePub)206012 hsv//eng
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Oftalmologi0 (SwePub)302172 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Ophthalmology0 (SwePub)302172 hsv//eng
650 7a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Annan medicinteknik0 (SwePub)206992 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Other Medical Engineering0 (SwePub)206992 hsv//eng
653 a resonance sensor
653 a intra-ocular pressure
653 a Medical engineering
653 a Medicinsk teknik
653 a Ophtalmiatrics
653 a Oftalmiatrik
653 a Ophtalmology
653 a oftalmiatrik
653 a Medical Engineering for Healthcare
700a Lindén, Christinau Umeå universitet,Institutionen för klinisk vetenskap,Umeå University, Department of Clinical Science, Ophthalmology4 aut0 (Swepub:umu)chli0002
700a Bäcklund, Tomasu Umeå universitet,Radiofysik,Umeå University Hospital, Department of Biomedical Engineering & Informatics4 aut0 (Swepub:umu)bato0003
700a Andersson, Britt M,d 1962-u Umeå universitet,Institutionen för tillämpad fysik och elektronik,Centrum för medicinsk teknik och fysik (CMTF),Umeå University. Department of Applied Physics and Electronics4 aut0 (Swepub:umu)bran0001
700a Lindahl, Olof A,d 1955-u Umeå universitet,Institutionen för tillämpad fysik och elektronik,Centrum för medicinsk teknik och fysik (CMTF)4 aut0 (Swepub:ltu)olofl
710a Umeå universitetb Radiofysik4 org
773t Medical and Biological Engineering and Computingg 41:2, s. 190-197q 41:2<190-197x 0140-0118x 1741-0444
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-19134
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-6797
8564 8u https://doi.org/10.1007/BF02344887

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy