Principle, calibration, and application of the in situ alkali chloride monitor
-
- Forsberg, Christer (författare)
- Vattenfall AB Nordic Heat, S-162 87 Stockholm, Sweden
-
- Broström, Markus, 1977- (författare)
- Umeå universitet,Energiteknik och termisk processkemi
-
- Backman, Rainer, 1952- (författare)
- Umeå universitet,Energiteknik och termisk processkemi
-
visa fler...
-
- Edvardsson, Elin (författare)
- Vattenfall Research and Development AB, S-814 26 Älvkarleby, Sweden
-
- Badiei, Shahriar (författare)
- Vattenfall Research and Development AB, S-814 26 Älvkarleby, Sweden
-
- Berg, Magnus (författare)
- Vattenfall Research and Development AB, S-814 26 Älvkarleby, Sweden
-
- Kassman, Håkan (författare)
- Vattenfall Power Consultant AB, Box 1046, S-611 29 Nyköping, Sweden
-
visa färre...
-
(creator_code:org_t)
- American Institute of Physics, 2009
- 2009
- Engelska.
-
Ingår i: Review of Scientific Instruments. - : American Institute of Physics. - 0034-6748 .- 1089-7623. ; 80:2, s. 023104-1-023104-4
- Relaterad länk:
-
http://link.aip.org/...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The extended use of biomass for heat and power production has caused increased operational problems with fouling and high-temperature corrosion in boilers. These problems are mainly related to the presence of alkali chlorides (KCl and NaCl) at high concentrations in the flue gas. The In-Situ Alkali Chloride Monitor (IACM) was developed by Vattenfall Research and Development AB for measuring the alkali chloride concentration in hot flue gases (>650 oC). The measurement technique is based on molecular differential absorption spectroscopy in the UV range. Simultaneous measurement of SO2 concentration is also possible. The measuring range is 1-50 ppm for the sum of KCl and NaCl concentrations, and 4-750 ppm for SO2. This paper describes the principle of the IACM as well as its calibration. Furthermore, an example of its application in an industrial boiler is given.
Nyckelord
- bioenergy conversion
- boilers
- corrosion
- flue gases
- gas sensors
- ultraviolet spectra
Publikations- och innehållstyp