Development of a miniaturized diffusive sampler for true breathing-zone sampling and thermal desorption gas chromatographic analysis

Lindahl, Roger (author)
Umeå universitet,Kemiska institutionen
Levin, Jan-Olof (author)
Umeå universitet,Kemiska institutionen,Fenix Environmental, SE- 907 19 Umeå, Sweden
Sundgren, Margit (author)
Fenix Environmental, SE- 907 19 Umeå, Sweden
 (creator_code:org_t)
Royal Society of Chemistry, 2009
2009
English.
In: Journal of Environmental Monitoring. - : Royal Society of Chemistry. - 1464-0325 .- 1464-0333. ; 11:7, s. 1340-1344
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Exposure measurements should be performed as close as possible to the nose and mouth for a more correct assessment of exposure. User-friendly sampling equipment, with a minimum of handling before, during and after measurement, should not affect ordinary work. In diffusive (passive) sampling, no extra equipment as sampling pumps is needed, making the measurements more acceptable to the user. The diffusive samplers are normally attached on a shoulder, on a breast-pocket or on the lapel. There are, however, difficulties if true breathing-zone sampling is to be performed, since available diffusive samplers normally cannot be arranged close to the nose/mouth. The purpose of this work was to study the performance of a miniaturized tube type diffusive sampler attached to a headset for true breathing-zone sampling. The basis for this miniaturization was the Perkin Elmer ATD tube. Both the size of the tube and the amount of adsorbent was decreased for the miniaturized sampler. A special tube holder to be used with a headset was designed for the mini tube. The mini tube is thermally desorbed inside a standard PE tube. The new sampler was evaluated for the determination of styrene, both in laboratory experiments and in field measurements. As reference method, diffusive sampling with standard Perkin Elmer tubes, thermal desorption and gas chromatographic (GC) analysis was used. The sampling rate was determined to 0.356 mL min-1 (CV 9.6%) and was not significantly affected by concentration, sampling time or relative humidity.  

Subject headings

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Lindahl, Roger
Levin, Jan-Olof
Sundgren, Margit
About the subject
NATURAL SCIENCES
NATURAL SCIENCES
and Chemical Science ...
Articles in the publication
Journal of Envir ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view