SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-26687"
 

Sökning: id:"swepub:oai:DiVA.org:umu-26687" > Instrument towards ...

Instrument towards faster diagnosis and treatment of prostate cancer : Resonance sensor stiffness measurements on human prostate tissue in vitro

Jalkanen, Ville, 1978- (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,Centrum för medicinsk teknik och fysik (CMTF),Umeå University. Department of Applied Physics and Electronics
Andersson, Britt (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,Centrum för medicinsk teknik och fysik (CMTF),Umeå University. Department of Applied Physics and Electronics
Lindahl, Olof (författare)
Luleå tekniska universitet,Signaler och system
 (creator_code:org_t)
Heidelberg : Springer, 2009
2009
Engelska.
Ingår i: IFMBE Proceedings of the World Congress on Medical Physics and Biomedical Engineering. - Heidelberg : Springer. ; , s. 145-148, s. 145-148
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Prostate cancer is the most common cancer among men and the methods used to detect and diagnose prostate cancer are not sufficiently accurate. Radical prostatectomy is a surgical treatment of prostate cancer where the whole prostate is removed from the patient. Prostate tissue stiffness can be measured with a stiffness sensitive resonance sensor. The aim of this study was to measure the stiffness on the anterior and posterior side of fresh human prostate tissue in vitro and compare these two groups with each other and relate the findings with the prostate tissue histology.  In a prostate tissue slice with mostly normal healthy tissue, the anterior side was significantly harder (p-value < 0.05) as expected. In a prostate tissue slice with areas of cancer tumors, no difference was found between the anterior and posterior sides. However, large stiffness variations were found within groups with measurements points on cancer tissue (coefficient of variation, CV = 42 and 85%), as opposed to groups without cancer tissue (CV = 27 and 28%).  The large stiffness variations could be used as a sign for the presence of cancer. The results are promising for the development of an instrument and method for faster diagnosis on radical prostatectomy samples.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Nyckelord

Prostate
cancer
diagnosis
resonance sensor
Medical engineering
Medicinsk teknik
Medical Engineering for Healthcare

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Jalkanen, Ville, ...
Andersson, Britt
Lindahl, Olof
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Annan medicintek ...
Artiklar i publikationen
Av lärosätet
Umeå universitet
Luleå tekniska universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy