SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:uu-220595"
 

Search: id:"swepub:oai:DiVA.org:uu-220595" > Accuracy of three a...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Accuracy of three activity monitors in patients with chronic obstructive pulmonary disease : A comparison with video recordings

Andersson, Mikael (author)
Uppsala universitet,Sjukgymnastik
Janson, Christer (author)
Uppsala universitet,Lungmedicin och allergologi
Emtner, Margareta (author)
Uppsala universitet,Sjukgymnastik,Lungmedicin och allergologi
 (creator_code:org_t)
2014-04-15
2014
English.
In: COPD. - : Informa UK Limited. - 1541-2555 .- 1541-2563. ; 11:5, s. 560-567
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Low physical activity and sedentary behaviour characterise the lives of patients with chronic obstructive pulmonary disease (COPD). Using activity monitors, assessment of both aspects are possible, but many outcomes are not well validated. The aim of this study was to assess the accuracy and equivalency of three activity monitors regarding steps, body position and their ability to differentiate between periods of physical activity and inactivity.Fifteen patients with COPD (8 females; median (interquartile range, IQR) age, 64 (59-69) years; forced expiratory volume in one second, 37 (28-48) % predicted; six-minute walk distance, 444 (410-519) m) were enrolled. The DynaPort ADL-monitor, the DynaPort MiniMod monitor and the SenseWear Armband Pro 3 monitor were assessed. Subjects performed a structured protocol alternating physical activity and inactivity while simultaneously wearing all three monitors and being video recorded. The mean difference (limits of agreement) in step count from monitors compared to manual step count was -69 (-443 to 305) for the ADL-monitor, -19 (-141 to 103) for the MiniMod and -479 (-855 to -103) for the SenseWear Armband. Compared to the video, the sitting time was 97 (94-100) % when measured by the ADL-monitor and 121 (110-139) % by the MiniMod. Standing time was 114 (107-122) % when measured by the ADL-monitor and 68 (47-106) % by the MiniMod. Activity monitors are not equivalent in their abilities to detect steps or body positions. The choice of monitor should be based on the particular outcome of interest. 

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Lungmedicin och allergi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Respiratory Medicine and Allergy (hsv//eng)

Keyword

Activity monitor
accuracy
validity
physical activity
sedentary
rehabilitation
Medical Science
Medicinsk vetenskap

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

  • COPD (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Andersson, Mikae ...
Janson, Christer
Emtner, Margaret ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Respiratory Medi ...
Articles in the publication
COPD
By the university
Uppsala University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view