SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:uu-372540"
 

Search: id:"swepub:oai:DiVA.org:uu-372540" > Characteristics of ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Libard, SylwiaUppsala universitet,Klinisk och experimentell patologi,Department of Pathology, Uppsala University Hospital, Uppsala, Sweden,Irina Alafuzoff (author)

Characteristics of the tissue section that influence the staining outcome in immunohistochemistry

  • Article/chapterEnglish2019

Publisher, publication year, extent ...

  • 2018-10-24
  • Springer Science and Business Media LLC,2019
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:uu-372540
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-372540URI
  • https://doi.org/10.1007/s00418-018-1742-1DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Immunohistochemistry (IHC) is influenced by several factors such as cold ischemia time, fixative, fixation time, paraffin, storage time, antibody, antigen retrieval technique and detection systems. In the setting of post-mortem tissue, not only post-mortem delay, but also agonal state is of interest. Here, we assessed an additional variable, i.e., the thickness of the section, and noted that this variable also influenced the IHC outcome. This is of significance when the extent of labelling is a parameter to be assessed, for example when assigning a stage or grade of a disease. Furthermore, when assessing brain tissue with neurons, soma measuring from 4 to 100 µm, various cellular compartments composed of different proteins are localised in sections measuring 4 or 7 µm. Thus, what is seen in a 7-µm-thick section might be lacking in a 4-µm-thick section. Lack of information regarding the molecular size of commercial antibodies is also disturbing as this parameter might influence the distribution of the molecule in the three-dimensional section. The choice of antibody to be used and the staining methodology have been acknowledged being of significance for IHC outcome; however, neither sections thickness or the molecular weight has been discussed sufficiently. IHC has been shown to be an unpredictable technique used for assessment of tissue. This emphasises the need for detailed methodological descriptions in publications, the need to acknowledge and to harmonize all eventual pitfalls related to this methodology.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Cerjan, DijanaDepartment of Pathology, Uppsala University Hospital, Uppsala, Sweden(Swepub:uu)dijce981 (author)
  • Alafuzoff, IrinaUppsala universitet,Klinisk och experimentell patologi,Department of Pathology, Uppsala University Hospital, Uppsala, Sweden,Irina Alafuzoff(Swepub:uu)irial548 (author)
  • Uppsala universitetKlinisk och experimentell patologi (creator_code:org_t)

Related titles

  • In:Histochemistry and Cell Biology: Springer Science and Business Media LLC151:1, s. 91-960948-61431432-119X

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Libard, Sylwia
Cerjan, Dijana
Alafuzoff, Irina
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Clinical Laborat ...
Articles in the publication
Histochemistry a ...
By the university
Uppsala University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view