SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:uu-409836"
 

Search: id:"swepub:oai:DiVA.org:uu-409836" > Time-Frequency and ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Time-Frequency and Energy Correlations of the Transient Voltages Triggered by Cloud to Cloud Discharges

Sapumanage, Nilantha (author)
Univ Colombo, Dept Phys, Colombo 0030, Sri Lanka.
Nanayakkara, Sankha (author)
Univ Colombo, Dept Phys, Colombo 0030, Sri Lanka.
Abegunawardana, Sidath (author)
Univ Colombo, Dept Phys, Colombo 0030, Sri Lanka.
show more...
Fernando, Mahendra (author)
Univ Colombo, Dept Phys, Colombo 0030, Sri Lanka.
Cooray, Vernon, 1952- (author)
Uppsala universitet,Elektricitetslära
show less...
Univ Colombo, Dept Phys, Colombo 0030, Sri Lanka Elektricitetslära (creator_code:org_t)
Institute of Electrical and Electronics Engineers (IEEE), 2019
2019
English.
In: IEEE transactions on electromagnetic compatibility (Print). - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9375 .- 1558-187X. ; 61:6, s. 1782-1792
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • This paper presents a study performed on time, frequency, and energy correlations of transient voltages generated by the cloud to cloud discharges. It revealed that the energy embedded in transient voltages have been lumped over few segments of time domain voltage profile than uniquely scattering over the time span. The study further determined that the energy concentration becomes higher in and around the vicinity of the time domain voltage maxima or minima, and such high energy-concentrated segments confined to a minute time span in comparison to the total time span of the transient voltage. The study also established that there is a small time lead or lag between the time domain voltage maxima or minima and the time of energy maximize. Moreover, the analysis deduced that the time lead or time lag phenomenon, is not sensitive to the orientation of the time domain voltage profile, but fuelled by the pulse type. The response time of surge protective devices can become crucial if the stipulated clamping voltages of the protection devices fall close to local peaks of the transient voltages.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Keyword

Bipolar
cloud to cloud
induced voltage
pulse-burst
spectrogram
SPD
unipolar
wavelet transform

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view