SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:uu-91654"
 

Sökning: id:"swepub:oai:DiVA.org:uu-91654" > Tomography for part...

Tomography for partial-defect verification : experiences from measurements using different devices

Jacobsson Svärd, Staffan (författare)
Uppsala universitet,Institutionen för kärn- och partikelfysik,Tillämpad kärnfysik
Håkansson, Ane (författare)
Uppsala universitet,Tillämpad kärnfysik
Bäcklin, Anders (författare)
Uppsala universitet,Tillämpad kärnfysik
visa fler...
Jansson, Peter, 1971- (författare)
Uppsala universitet,Institutionen för strålningsvetenskap
Osifo, Otasowie (författare)
Uppsala universitet,Institutionen för strålningsvetenskap
Willman, Christofer (författare)
Uppsala universitet,Institutionen för strålningsvetenskap
visa färre...
 (creator_code:org_t)
2006
2006
Engelska.
Ingår i: ESARDA Bulletin. - 0392-3029. ; 33, s. 15-25
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Three devices of different types have been used in tomographic measurements for the purpose of partial-defect verification on the single-rod level. The devices range from a laboratory device used in measurements on a fuel model to an in-pool device used in measurements on irradiated fuel in a fuel-handling pool.The tomographic technique accounted for in this paper involves measurements of the gamma-ray flux distribution around a fuel assembly followed by computer-aided reconstruction of the internal source distribution. The results are rod-by-rod values of the relative concentrations of selected gamma-emitting isotopes. Also cross-sectional images are obtained.The tomographic technique presented here has proven to be robust and reliable. In laboratory experiments on a fuel model, reconstructions of relative rod-by-rod activities have been obtained with 1.5 % accuracy (1 σ). Using an in-pool device in measurements on fuel with a cooling time of about 4 weeks, data on fuel rods have been obtained in agreement with production-code calculations. Furthermore, tomographic images of good quality have been acquired.The applicability of the tomographic technique for partial-defect verification on the single-rod level has been investigated and demonstrated. The gamma-ray source concentration reconstructed in a position corresponding to a removed or replaced rod has been significantly lower than that of normal rods.Finally, requirements and properties of a device for tomographic measurements on nuclear fuel are discussed. It is argued that the use of a detector system with high energy resolution and high peak efficiency in connection to spectroscopic peak analysis is beneficial.

Ämnesord

NATURVETENSKAP  -- Fysik -- Subatomär fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Subatomic Physics (hsv//eng)

Nyckelord

tomography
Applied Nuclear Physics
Tillämpad kärnfysik
Fysik med inriktning mot tillämpad kärnfysik
Physics with specialization in Applied Nuclear Physics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy