2451 0a The benefit of accounting for DQE variations in simulated dose reduction of digital radiographic systems
264 c 2010-02-22
264 1b Oxford University Press (OUP),c 2010
520 a Adding noise to clinical radiographs to simulate dose reduction can be used to investigate the relationship between dose level and clinical image quality without exposing patients to additional radiation. The purpose of the present paper was to examine the benefits of using a method that accounts for detective quantum efficiency (DQE) variations that may occur in different dose ranges in the simulated dose reduction process. A method initially intended for simulated dose reduction in tomosynthesis was applied to extremely low-dose posterioanterior radiographs of an anthropomorphic chest phantom, selected from a group of projection images included in a tomosynthesis examination and compared with a previous method that do not account for DQE variations. A comparison of images simulated to be collected at a lower dose level (73 % of the original dose level) and images actually collected at this lower dose level revealed that the error in the integrated normalised noise power spectrum was smaller than 4 % for the method that accounts for DQE variations in the simulated dose reduction, whereas the error was larger than 20 % for the previous method. This indicates that an increased validity in dose reduction simulation of digital radiographic systems is obtained with a method accounting for DQE variations.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
700a Båth, Magnus,d 1974u Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics4 aut0 (Swepub:gu)xbatma
710a Göteborgs universitetb Institutionen för kliniska vetenskaper, Avdelningen för radiofysik4 org
773t Radiation protection dosimetryd : Oxford University Press (OUP)g 139:1-3, s. 57-61q 139:1-3<57-61x 1742-3406x 0144-8420
8564 8u https://gup.ub.gu.se/publication/117589
8564 8u https://doi.org/10.1093/rpd/ncq058

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Svalkvist, Angel ...
Båth, Magnus, 19 ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Radiation protec ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy