SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:gup.ub.gu.se/119418"
 

Search: id:"swepub:oai:gup.ub.gu.se/119418" > Monte Carlo simulat...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Monte Carlo simulations of the dosimetry of chest tomosynthesis

Svalkvist, Angelica (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Månsson, Lars Gunnar, 1951 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Båth, Magnus, 1974 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
 (creator_code:org_t)
2010-03-03
2010
English.
In: Radiation protection dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 139:1-3, s. 144-152
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The aims of this work were to explore the dosimetry of chest tomosynthesis and to determine conversion factors between air kerma-area product (KAP) and the effective dose for different system configurations and patient sizes. Tomosynthesis systems were modelled with different angular intervals and tube voltages for the collection of the projection images as well as different distributions of the total exposure over the projections. The Monte Carlo-based computer software PCXMC developed by STUK (Radiation and Nuclear Safety Authority in Finland) was used to calculate the effective doses for each modelled tomosynthesis system for various patient sizes. The conversion factor between KAP and effective dose was obtained both for the zero-degree projection alone and for the entire tomosynthesis examination for each system configuration and patient size. The results reveal that the conversion factor for the zero-degree projection can be used to estimate the total effective dose from a tomosynthesis examination with acceptable accuracy, leading to an error smaller than 10 % irrespective of the system configuration and patient size. For higher accuracy, conversion factors between the total KAP and the total effective dose that take the angular interval and exposure configuration into account are presented for each system.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Svalkvist, Angel ...
Månsson, Lars Gu ...
Båth, Magnus, 19 ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Radiation protec ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view