2451 0a A phantom study of nodule size evaluation with chest tomosynthesis and computed tomography.
264 c 2010-02-04
264 1b Oxford University Press (OUP),c 2010
520 a The aim of the present study was to investigate nodule size measurements with chest tomosynthesis (TS) and computed tomography (CT). A 26-mm thick phantom, composed of a Polylite block with embedded spheres of different materials and sizes (4-20 mm), was scanned by both CT and TS. Six observers without prior knowledge of the true diameters of the spheres independently measured the diameter of the spheres on the CT and TS images. Four observers were allowed to change the window settings and two of the observers used predetermined fixed viewing conditions. The mean relative errors for all observers and all measured spheres compared with the known diameter of the spheres were 1.4 % (standard deviation, SD: 5.4 %) on CT images and -1.1 % (SD: 5.0 %) on TS images. With regard to the four observers where the window settings were at the discretion of the observer, the mean relative errors were 1.4 % (SD: 6.4 %) on CT images and -1.7 % (SD: 5.7 %) on TS images. Regarding the two observers using identical viewing conditions the mean relative error was 1.5 % (SD: 2.8 %) on CT images and 0.2 % (SD: 2.6 %) on TS images. In conclusion, the study suggests that nodule size measurements on chest TS might be an alternative to measurements on CT.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
653 a Algorithms
653 a Humans
653 a Lung Neoplasms
653 a radiography
653 a Phantoms
653 a Imaging
653 a Radiographic Image Enhancement
653 a methods
653 a Radiographic Image Interpretation
653 a Computer-Assisted
653 a methods
653 a Radiography
653 a Thoracic
653 a methods
653 a Reproducibility of Results
653 a Sensitivity and Specificity
653 a Solitary Pulmonary Nodule
653 a radiography
653 a Tomography
653 a X-Ray Computed
653 a methods
700a Svalkvist, Angelicau Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics4 aut0 (Swepub:gu)xsvala
700a Vikgren, Jenny,d 1957u Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology4 aut0 (Swepub:gu)xvikje
700a Boijsen, Marianne,d 1948u Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology4 aut0 (Swepub:gu)xboima
700a Flinck, Agneta,d 1953u Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology4 aut0 (Swepub:gu)xfliag
700a Kheddache, Susanne,d 1949u Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology4 aut0 (Swepub:gu)xkhesu
700a Båth, Magnus,d 1974u Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics4 aut0 (Swepub:gu)xbatma
710a Göteborgs universitetb Institutionen för kliniska vetenskaper, Avdelningen för radiologi4 org
773t Radiation protection dosimetryd : Oxford University Press (OUP)g 139:1-3, s. 140-143q 139:1-3<140-143x 1742-3406x 0144-8420
8564 8u https://gup.ub.gu.se/publication/144793
8564 8u https://doi.org/10.1093/rpd/ncq003

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy