SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/203882"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/203882" > Experimental and co...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003621naa a2200529 4500
001oai:gup.ub.gu.se/203882
003SwePub
008240528s2014 | |||||||||||000 ||eng|
024a https://gup.ub.gu.se/publication/2038822 URI
024a https://doi.org/10.1177/09544119145455562 DOI
040 a (SwePub)gu
041 a eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Bressan, E.4 aut
2451 0a Experimental and computational investigation of Morse taper conometric system reliability for the definition of fixed connections between dental implants and prostheses
264 c 2014-07-23
264 1b SAGE Publications,c 2014
520 a Nowadays, dental implantology is a reliable technique for treatment of partially and completely edentulous patients. The achievement of stable dentition is ensured by implant-supported fixed dental prostheses. Morse taper conometric system may provide fixed retention between implants and dental prostheses. The aim of this study was to investigate retentive performance and mechanical strength of a Morse taper conometric system used as implant-supported fixed dental prostheses retention. Experimental and finite element investigations were performed. Experimental tests were achieved on a specific abutment-coping system, accounting for both cemented and non-cemented situations. The results from the experimental activities were processed to identify the mechanical behavior of the coping-abutment interface. Finally, the achieved information was applied to develop reliable finite element models of different abutment-coping systems. The analyses were developed accounting for different geometrical conformations of the abutment-coping system, such as different taper angle. The results showed that activation process, occurred through a suitable insertion force, could provide retentive performances equal to a cemented system without compromising the mechanical functionality of the system. These findings suggest that Morse taper conometrical system can provide a fixed connection between implants and dental prostheses if proper insertion force is applied. Activation process does not compromise the mechanical functionality of the system.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Odontologi0 (SwePub)302162 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Dentistry0 (SwePub)302162 hsv//eng
653 a Dental implantology
653 a Morse taper conometric system
653 a mechanical
653 a properties
653 a SURFACE-ROUGHNESS
653 a BITE FORCE
653 a ATTACHMENT SYSTEMS
653 a STUD ATTACHMENTS
653 a RETENTIVE FORCE
653 a OVERDENTURES
653 a RESTORATIONS
653 a DENTITION
653 a FRICTION
653 a DENTURES
653 a Engineering
653 a Biomedical
700a Lops, D.4 aut
700a Tomasi, Cristiano,d 1964u Gothenburg University,Göteborgs universitet,Institutionen för odontologi,Institute of Odontology4 aut0 (Swepub:gu)xtomcr
700a Ricci, S.4 aut
700a Stocchero, M.4 aut
700a Carniel, E. L.4 aut
710a Göteborgs universitetb Institutionen för odontologi4 org
773t Proceedings of the Institution of Mechanical Engineers Part H-Journal of Engineering in Medicined : SAGE Publicationsg 228:7, s. 674-681q 228:7<674-681x 0954-4119x 2041-3033
8564 8u https://gup.ub.gu.se/publication/203882
8564 8u https://doi.org/10.1177/0954411914545556

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bressan, E.
Lops, D.
Tomasi, Cristian ...
Ricci, S.
Stocchero, M.
Carniel, E. L.
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Proceedings of t ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy