SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:gup.ub.gu.se/234499"
 

Sökning: id:"swepub:oai:gup.ub.gu.se/234499" > (2016) > The effect of Adapt...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003097naa a2200313 4500
001oai:gup.ub.gu.se/234499
003SwePub
008240528s2016 | |||||||||||000 ||eng|
024a https://gup.ub.gu.se/publication/2344992 URI
024a https://doi.org/10.1093/rpd/ncv5582 DOI
040 a (SwePub)gu
041 a eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Larsson, Joel,d 1986u Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics4 aut0 (Swepub:gu)xlajoe
2451 0a The effect of Adaptive Statistical iterative Reconstruction (ASiR) on the assessment of diagnostic quality and visualisation of anatomical structures in paediatric head CT examinations
264 c 2016-02-11
264 1b Oxford University Press (OUP),c 2016
520 a The purpose of this study was to investigate the effect of adaptive statistical iterative reconstruction (ASiR) on the visualisation of anatomical structures and diagnostic image quality in paediatric cerebral computed tomography (CT) examinations. Forty paediatric patients undergoing routine cerebral CT were included in the study. The raw data from CT scans were reconstructed into stacks of 5 mm thick axial images at various levels of ASiR. Three paediatric radiologists rated six questions related to the visualisation of anatomical structures and one question on diagnostic image quality, in a blinded randomised visual grading study. The evaluated anatomical structures demonstrated enhanced visibility with increasing level of ASiR, apart from the cerebrospinal fluid space around the brain. In this study, 60 % ASiR was found to be the optimal level of ASiR for paediatric cerebral CT examinations. This shows that the commonly used 30 % ASiR may not always be the optimal level.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
700a Båth, Magnus,d 1974u Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics4 aut0 (Swepub:gu)xbatma
700a Ledenius, Kerstin,d 19794 aut
700a Thilander-Klang, Anne,d 1959u Gothenburg University,Göteborgs universitet,Extern,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,External,Institute of Clinical Sciences, Department of Radiation Physics4 aut0 (Swepub:gu)xthian
710a Göteborgs universitetb Institutionen för kliniska vetenskaper, Avdelningen för radiofysik4 org
773t Radiation protection dosimetryd : Oxford University Press (OUP)g 169:1-4, s. 115-122q 169:1-4<115-122x 1742-3406x 0144-8420
8564 8u https://gup.ub.gu.se/publication/234499
8564 8u https://doi.org/10.1093/rpd/ncv558

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy