Sökning: id:"swepub:oai:lup.lub.lu.se:120be11e-0c19-4fad-83e9-91f839d24087" >
A method for the de...
A method for the design and study of enzyme microstructures formed by means of a flow-through microdispenser
-
Gaspar, S. (författare)
-
Mosbach, M. (författare)
-
Wallman, L. (författare)
-
visa fler...
-
- Laurell, Thomas (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Csöregi, Elisabeth (författare)
- Lund University,Lunds universitet,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
Schuhmann, W. (författare)
-
visa färre...
-
(creator_code:org_t)
- 2001-08-07
- 2001
- Engelska.
-
Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 1520-6882 .- 0003-2700. ; 73:17, s. 4254-4261
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Micrometer-sized enzyme grids were fabricated on gold surfaces using a novel method based on a flow-through microdispenser. The method involves dispensing very small droplets of enzyme solution (similar to 100 pL) during the concomitant relative movement of a gold substrate with respect to the nozzle of a microdispenser, resulting in enzyme patterns with a line width of similar to 100 mum. Different immobilization methods have been evaluated, yielding either enzyme monolayers using functionalized self-assembled thiol monolayers for covalent binding of the enzyme or enzyme multilayers by cross-linking or entrapping the enzymes in a polymer film. The latter immobilization techniques allow the formation of coupled multienzyme structures. On the basis of this feature, coupled bienzyme (glucose oxidase and catalase) or three-enzyme (alpha -glucosidase, mutarotase, and glucose oxidase) microstructures consisting of line patterns of one enzyme intersecting with the patterned lines of the other enzyme(s) were fabricated. By means of scanning electrochemical microscopy (SECM) operated in the generator-collector mode, the enzyme microstructures and their integrity were visualized using the localized detection of enzymatically produced/consumed H2O2. A calibration curve for glucose could be obtained by subsequent SECM line scans over a glucose oxidase microstructure for increasing glucose concentrations, demonstrating the possibility of obtaining localized quantitative data from the prepared microstructures. Possible applications of these enzyme microstructures for multianalyte detection and interference elimination and for screening of different biosensor configurations are highlighted.
Ämnesord
- NATURVETENSKAP -- Kemi -- Analytisk kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
Nyckelord
- SCANNING ELECTROCHEMICAL MICROSCOPY
- DIP-PEN NANOLITHOGRAPHY
- NANOSTRUCTURES
- CHROMATOGRAPHY
- FABRICATION
- GENERATION
- ELECTRODE
- DISPENSER
- SURFACES
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas