SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:lup.lub.lu.se:7a52c041-8cab-4eb0-b840-c1412822dfcc"
 

Search: id:"swepub:oai:lup.lub.lu.se:7a52c041-8cab-4eb0-b840-c1412822dfcc" > Microembolic signal...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Microembolic signal counts increase during hyperbaric exposure in patients with prosthetic heart valves

Baumgartner, R W (author)
Frick, A (author)
Kremer, Christine (author)
Lund University,Lunds universitet,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
show more...
Oechslin, E (author)
Russi, E (author)
Turina, J (author)
Georgiadis, D (author)
show less...
 (creator_code:org_t)
Elsevier BV, 2001
2001
English.
In: Journal of Thoracic and Cardiovascular Surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; 122:6, s. 1142-1146
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND: Patients with prosthetic heart valves have an increased risk of thromboembolic events, and transcranial Doppler sonography reveals microembolic signals. Whereas microembolic signals were initially assumed to be of particulate matter, recent studies suggest that they are partially gaseous in origin. If this is true, alteration of environmental pressure should change microembolic signal counts. We undertook this study to evaluate the influence of hyperbaric exposure on microembolic signal counts in persons with prosthetic heart valves. METHODS AND RESULTS: Microembolic signal counts were monitored by transcranial Doppler sonography of both middle cerebral arteries under normobaria (normobaria 1), 2 subsequent periods of hyperbaria (2.5 and 1.75 bar), and a second period of normobaria (normobaria 2) in 15 patients with prosthetic heart valves. Each monitoring period lasted 30 minutes. Compression and decompression rates were 0.1 bar/min. Microembolic signal counts increased from 20 (12-78) at normobaria 1 to 79 (30-165) at 2.5 bar (P <.01 vs normobaria 1 and 2), decreased to 44 (18-128) at 1.75 bar (P <.01 vs normobaria 1 and 2.5 bar; P <.001 vs normobaria 2), and returned to 20 (8-96) at normobaria 2 (values are medians and 95% confidence intervals). CONCLUSIONS: Our results strongly suggest that gaseous bubbles are underlying material for part of the microembolic signals detected in patients with prosthetic heart valves.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view