Microembolic signal counts increase during hyperbaric exposure in patients with prosthetic heart valves
-
Baumgartner, R W (author)
-
Frick, A (author)
-
- Kremer, Christine (author)
- Lund University,Lunds universitet,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
-
show more...
-
Oechslin, E (author)
-
Russi, E (author)
-
Turina, J (author)
-
Georgiadis, D (author)
-
show less...
-
(creator_code:org_t)
- Elsevier BV, 2001
- 2001
- English.
-
In: Journal of Thoracic and Cardiovascular Surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; 122:6, s. 1142-1146
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
http://www.jtcvs.org...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- BACKGROUND: Patients with prosthetic heart valves have an increased risk of thromboembolic events, and transcranial Doppler sonography reveals microembolic signals. Whereas microembolic signals were initially assumed to be of particulate matter, recent studies suggest that they are partially gaseous in origin. If this is true, alteration of environmental pressure should change microembolic signal counts. We undertook this study to evaluate the influence of hyperbaric exposure on microembolic signal counts in persons with prosthetic heart valves. METHODS AND RESULTS: Microembolic signal counts were monitored by transcranial Doppler sonography of both middle cerebral arteries under normobaria (normobaria 1), 2 subsequent periods of hyperbaria (2.5 and 1.75 bar), and a second period of normobaria (normobaria 2) in 15 patients with prosthetic heart valves. Each monitoring period lasted 30 minutes. Compression and decompression rates were 0.1 bar/min. Microembolic signal counts increased from 20 (12-78) at normobaria 1 to 79 (30-165) at 2.5 bar (P <.01 vs normobaria 1 and 2), decreased to 44 (18-128) at 1.75 bar (P <.01 vs normobaria 1 and 2.5 bar; P <.001 vs normobaria 2), and returned to 20 (8-96) at normobaria 2 (values are medians and 95% confidence intervals). CONCLUSIONS: Our results strongly suggest that gaseous bubbles are underlying material for part of the microembolic signals detected in patients with prosthetic heart valves.