SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:lup.lub.lu.se:7d28a1cd-ba16-4209-937c-379a47c50fd4"
 

Search: id:"swepub:oai:lup.lub.lu.se:7d28a1cd-ba16-4209-937c-379a47c50fd4" > Wound edge microvas...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Wound edge microvascular blood flow during negative-pressure wound therapy: examining the effects of pressures from -10 to -175 mmHg.

Borgquist, Ola (author)
Lund University,Lunds universitet,Oftalmologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Ophthalmology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
Ingemansson, Richard (author)
Lund University,Lunds universitet,Thoraxkirurgi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Thoracic Surgery,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Malmsjö, Malin (author)
Lund University,Lunds universitet,Oftalmologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Ophthalmology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
2010
2010
English.
In: Plastic and Reconstructive Surgery. - 0032-1052. ; 125:2, s. 502-509
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND: Negative-pressure wound therapy is believed to accelerate wound healing by altered wound edge microvascular blood flow. The current standard negative pressure is -125 mmHg. However, this pressure may cause pain and ischemia and often has to be reduced. The aim of the present study was to examine the blood flow effects of different levels of negative pressures (-10 to -175 mmHg). METHODS: Wound edge microvascular blood flow was studied in a peripheral wound model in eight 70-kg pigs on application of negative-pressure wound therapy. Blood flow was examined, using laser Doppler velocimetry, in subcutaneous and muscle tissue at 0.5, 2.5, and 5 cm from the wound edge. RESULTS: Blood flow changed gradually with increasing negative pressure until reaching a steady state. Blood flow decreased close to the wound edge (0.5 cm) and increased farther from the wound edge (2.5 cm). At 0.5 cm, blood flow decreased 15 percent at -10 mmHg, 64 percent at -45 mmHg, and 97 percent at -80 mmHg. At 2.5 cm, blood flow increased 6 percent at -10 mmHg, 32 percent at -45 mmHg, and 90 percent at -80 mmHg. Higher levels of negative pressure did not have additional blood flow effects (p > 0.30). No blood flow effects were seen 5 cm from the wound edge. CONCLUSIONS: Blood flow changes gradually when the negative pressure is increased. The levels of pressure for negative-pressure wound therapy may be tailored depending on the wound type and tissue composition, and this study implies that -80 mmHg has similar blood flow effects as the clinical standard, -125 mmHg.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Borgquist, Ola
Ingemansson, Ric ...
Malmsjö, Malin
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Surgery
Articles in the publication
Plastic and Reco ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view