SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:lup.lub.lu.se:904874b9-d914-48c8-874c-3c0ea574da86"
 

Search: id:"swepub:oai:lup.lub.lu.se:904874b9-d914-48c8-874c-3c0ea574da86" > Elimination of S100...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Elimination of S100B and renal function after cardiac surgery

Bjursten, Henrik (author)
Lund University,Lunds universitet,Thoraxkirurgi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Thoracic Surgery,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Johnsson, Per (author)
Höglund, Peter (author)
Lund University,Lunds universitet,Avdelningen för klinisk kemi och farmakologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Clinical Chemistry and Pharmacology,Department of Laboratory Medicine,Faculty of Medicine
show more...
Alling, Christer (author)
Lund University,Lunds universitet,Avdelningen för klinisk kemi och farmakologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Clinical Chemistry and Pharmacology,Department of Laboratory Medicine,Faculty of Medicine
Blomquist, Sten (author)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
show less...
 (creator_code:org_t)
Elsevier BV, 2000
2000
English.
In: Journal of Cardiothoracic and Vascular Anesthesia. - : Elsevier BV. - 1532-8422 .- 1053-0770. ; 14:6, s. 698-701
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • OBJECTIVES: To determine the biologic half-life of the S100B protein and to investigate if the elimination of S100B depends on glomerular filtration rate (GFR). DESIGN: Prospective human study. SETTING: University hospital. PARTICIPANTS: Sixteen patients who underwent cardiac surgery with cardiopulmonary bypass. INTERVENTIONS: Shed mediastinal blood (autotransfusion) was returned to the patients postoperatively and used to study the kinetics of S100B. Iohexol was infused simultaneously to estimate GFR. S100B was measured at 0, 20, 40, 60, and 180 minutes after infusion. Iohexol was measured at 180 and 240 minutes after infusion. MEASUREMENTS AND MAIN RESULTS: S100B followed first-order kinetics, and the biologic half-life for S100B was determined to be 25.3 +/- 5.1 minutes. GFR was determined to be 63.8 +/- 34.4 mL/min. No correlation was found between GFR and S100B half-life. CONCLUSIONS: The elimination of S100B after cardiac surgery is faster than reported earlier and not affected by a moderate decrease in GFR. This finding is important when evaluating S100B levels after cardiac surgery.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Bjursten, Henrik
Johnsson, Per
Höglund, Peter
Alling, Christer
Blomquist, Sten
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Cardiac and Card ...
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Anesthesiology a ...
Articles in the publication
Journal of Cardi ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view