SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:lup.lub.lu.se:a2d5c23f-eae1-40d9-8669-13bfe8349f97"
 

Search: id:"swepub:oai:lup.lub.lu.se:a2d5c23f-eae1-40d9-8669-13bfe8349f97" > A capacitive DNA se...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

A capacitive DNA sensor-based test for simple and sensitive analysis of antibiotic resistance in field setting.

Liu, Yanling (author)
Hedström, Martin (author)
Chen, Dongfeng (author)
Lund University,Lunds universitet,Neurokirurgi,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Neurosurgery,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
show more...
Fan, Xiaolong (author)
Lund University,Lunds universitet,Neurokirurgi,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Neurosurgery,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
Mattiasson, Bo (author)
show less...
 (creator_code:org_t)
Elsevier BV, 2015
2015
English.
In: Biosensors & Bioelectronics. - : Elsevier BV. - 1873-4235 .- 0956-5663. ; 64, s. 255-259
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • To meet urgent needs for solving serious worldwide drug-resistance problems, a sensitive label-free capacitive sensor developed in our group was investigated as a tool to be applied in the field of antibiotic resistance genotyping, for instance the detection of ampicillin resistance gene (ampR). Proof-of-concept data demonstrated its detection sensitivity of pico-molar without any signal amplification step and a dynamic range of at least three orders of magnitude. The detection limits of less than 1pM for the single-stranded ampR oligonucleotide and 4pM for the double-stranded target can reliably be achieved after only 2.5min sample reaction. Reusability of the probe-functionalized disposable electrode was investigated by comparing different regeneration solutions; mix of 25mM NaOH/30% formamide was employed to regenerate the electrode for at least six cycles without significant loss of sensing ability. Assay is performed automatically and result is retrieved in 20min. The developed sensitive genotyping tool is expected to provide simple, fast and affordable screening for monitoring spread of antibiotic resistances, which is suitable for testing in field setting.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Liu, Yanling
Hedström, Martin
Chen, Dongfeng
Fan, Xiaolong
Mattiasson, Bo
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Surgery
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Neurology
Articles in the publication
Biosensors & Bio ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view