Search: id:"swepub:oai:lup.lub.lu.se:c8935c4c-35bc-4973-9d66-e185a440c974" >
Efficient sample pr...
Efficient sample preparation in immuno-matrix-assisted laser desorption/ionization mass spectrometry using acoustic trapping
-
- Hammarström, Björn (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Yan, Hong (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Nilsson, Johan (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
show more...
-
- Ekström, Simon (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
show less...
-
(creator_code:org_t)
- AIP Publishing, 2013
- 2013
- English.
-
In: Biomicrofluidics. - : AIP Publishing. - 1932-1058. ; 7:2
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
https://europepmc.or...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- Acoustic trapping of minute bead amounts against fluid flow allows for easy automation of multiple assay steps, using a convenient aspirate/dispense format. Here, a method based on acoustic trapping that allows sample preparation for immuno-matrix-assisted laser desorption/ionization mass spectrometry using only half a million 2.8 mu m antibody covered beads is presented. The acoustic trapping is done in 200 x 2000 mu m2 glass capillaries and provides highly efficient binding and washing conditions, as shown by complete removal of detergents and sample processing times of 5-10 min. The versatility of the method is demonstrated using an antibody against Angiotensin I (Ang I), a peptide hormone involved in hypotension. Using this model system, the acoustic trapping was efficient in enriching Angiotensin at 400 pM spiked in plasma samples. (C) 2013 American Institute of Physics. [http://dx.doi.org/10.1063/1.4798473]
Subject headings
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering (hsv//eng)
Keyword
- acoustic applications
- biological specimen preparation
- molecular
- biophysics
- organic compounds
- time of flight mass spectroscopy
Publication and Content Type
- art (subject category)
- ref (subject category)
Find in a library
To the university's database