SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:d0b19dce-8833-4b47-b878-ad24220e1757"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:d0b19dce-8833-4b47-b878-ad24220e1757" > Real-time imaging t...

Real-time imaging through optical fiber array-assisted laser-induced fluorescence of capillary electrophoretic enantiomer separations

Johansson, T (författare)
Petersson, M (författare)
Johansson, Jonas (författare)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Nilsson, S (författare)
visa färre...
 (creator_code:org_t)
1999-09-03
1999
Engelska.
Ingår i: Analytical Chemistry. - : American Chemical Society (ACS). - 1520-6882 .- 0003-2700. ; 71:19, s. 4190-4197
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • An advanced detection system based on laser-induced fluorescence imaging for capillary electrophoresis (CE) is presented. An optical fiber array was constructed for collection and transportation of the emitted fluorescent light to the charge-coupled device (CCD) camera. The fiber array makes the setup compact compared with a setup where the capillary is imaged through a camera objective. The imaging detector captures the sample zones in motion during the migration through the capillary. This allows unique studies on dynamic events otherwise unrevealed. During the study, unexplained nonlinear migration behavior was revealed. Enantiomer separations of dansylated amino acids using cyclodextrins, imaged between 1.5 and 12 cm of a 28-cm-long 50-mu m i.d. capillary, were used for evaluation of the system. Comparing the optical fiber array with a camera lens system, the signal-to-noise-ratio (S/N) was 10 times higher. This is due to a combination of both higher signal and lower noise levels. To improve the S/N ratio further, a computer program for signal processing was designed. Using dichlorofluorescein, a concentration limit of detection (CLOD) of 350 pM was achieved and improved 10 times to 35 pM with computer postprocessing using 79 images. This is equal to 400 zeptomole for a 3-mm-long sample zone in a 50-mu m i.d. capillary.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Johansson, T
Petersson, M
Johansson, Jonas
Nilsson, S
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Analytical Chemi ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy