Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucoma

Bengtsson, B (author)
Lund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups
Heijl, A (author)
Lund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups
 (creator_code:org_t)
1998
1998
English 5 s.
In: Acta Ophthalmologica Scandinavica. - 1395-3907. ; 76:3, s. 72-268
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • PURPOSE: To evaluate the performance of the new perimetric threshold strategy SITA relative to older methods.METHOD: Thirty-two patients with either glaucoma or ocular hypertension performed two threshold visual field tests with each of three threshold strategies, SITA, Humphrey Full Threshold, and Fastpac. Testing was distributed over three visits, and testing order was balanced between strategies to control for order effects.RESULTS: SITA tests consumed 54% of the time taken by Full Threshold tests on average, and 85% of Fastpac tests; SITA's test times were significantly shorter than those of Full Threshold (p<0.0001) and Fastpac (p=0.0008). Test-retest threshold variability did not differ significantly between strategies. Intertest variability of the pattern deviation analysis was lowest in SITA (p<0.01) relative to both Full Threshold and Fastpac. Both SITA and Fastpac showed higher than expected average sensitivities relative to Full Threshold. SITA and Fastpac showed approximately the same amount of visual field loss. There was a significant relationship between Mean Deviation and the SITA function used to shorten stimulus sequences at points where measurement errors are small (p<0.0001).CONCLUSION: Our results suggest that SITA matches the precision of older thresholding methods, consuming considerably and significantly less test time. This indicates that SITA could replace Full Threshold as the standard clinical test used in glaucoma management, without decreasing the quality of test results.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Keyword

Aged
Aged, 80 and over
Algorithms
Evaluation Studies as Topic
Glaucoma
Humans
Middle Aged
Ocular Hypertension
Reproducibility of Results
Sensitivity and Specificity
Sensory Thresholds
Vision Disorders
Visual Field Tests
Visual Fields

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Bengtsson, B
Heijl, A
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Ophthalmology
Articles in the publication
Acta Ophthalmolo ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view