Effects of high photon fluence rate from therapeutic radionuclides on preclinical and clinical PET systems

Dahlbom, Magnus (author)
University of California, Los Angeles
Mellhammar, Emma (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Axelsson, Johan (author)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
show more...
Tran, Thuy (author)
Lund University,Lunds universitet,Lund University Bioimaging Center,Medicinska fakulteten,Faculty of Medicine
Strand, Sven Erik (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,University of California, Los Angeles
show less...
 (creator_code:org_t)
2016
2016
English.
In: 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014. - 9781479960972
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • Tumor response in radionuclide therapy can be monitored with PET/CT and/or PET/MR. A high background photon fluence from a therapy radionuclide may influence both image quality and quantification, when imaging is performed intra-therapeutically, i.e. with high activity of the therapeutic radionuclide present. Here, count losses and image distortion have been investigated for preclinical and clinical PET systems with different detector designs. The effect on the spatial resolution was studied with a point source of 22Na in a background of 99mTc, where 99mTc emulated the photon emission from a therapeutic radionuclide. An in-house made mouse phantom with silicon tubes filled with 99mTc with a centrally placed 22Na point source was used. For the clinical systems, a 70 cm long NEMA PET Scatter Phantom was used, with a 22Na point source placed at the center whereas the off-center silicon tube was filled with 99mTc. In addition, image quality was also evaluated in the presence of different levels of 99mTc with a 18F-filled NEMA image quality phantom on the preclinical systems and a 18F-filled Jaszczak phantom on the clinical system. Preclinical PET systems with different detector geometries showed that the addition of 99mTc affected the count rate capability considerably, especially those with a low number of read-out channels. The coincidence rate for was significantly reduced when high activities of 99mTc were present. The clinical PET system also showed an effect of reduced coincidence rate with increased photon fluence rate. At high 99mTc activities, the spatial resolution was degraded for both the preclinical and the clinical systems. The quantitative capability of PET systems used intra-therapeutically is significantly affected by the additional high photon fluence rate. The dead-time correction implemented on some of the investigated PET systems, was able to accurately compensate for the coincidence count losses. The reduced spatial resolution at high photon fluence rate, however, remains a potentially limiting factor.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

kon (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Dahlbom, Magnus
Mellhammar, Emma
Axelsson, Johan
Tran, Thuy
Strand, Sven Eri ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
2014 IEEE Nuclea ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view