SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:0a3727cb-2306-4c6b-a40f-f8e0ab87a5bb"
 

Sökning: id:"swepub:oai:research.chalmers.se:0a3727cb-2306-4c6b-a40f-f8e0ab87a5bb" > Firing of coal and ...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003490naa a2200457 4500
001oai:research.chalmers.se:0a3727cb-2306-4c6b-a40f-f8e0ab87a5bb
003SwePub
008171006s2007 | |||||||||||000 ||eng|
024a https://research.chalmers.se/publication/777232 URI
024a https://doi.org/10.1016/j.fuel.2007.04.0062 DOI
040 a (SwePub)cth
041 a engb eng
042 9 SwePub
072 7a art2 swepub-publicationtype
072 7a ref2 swepub-contenttype
100a Nevalainen, H.u Teknologian Tutkimuskeskus (VTT),Technical Research Centre of Finland (VTT)4 aut
2451 0a Firing of coal and biomass and their mixtures in 50 kW and 12 MW circulating fluidized beds - Phenomenon study and comparison of scales
264 1b Elsevier BV,c 2007
520 a The combustion dynamics of coal, wood chips and their mixture is investigated. Load change capability and the effect of the individual control variables, for example the mixture ratio of different fuels, on pilot-scale CFB boiler dynamics were also studied. Disturbances in fuel feeding cause fluctuations in the flue gas concentrations. Changes in the heating value are possible due to varying moisture content of the fuel. Both these disturbances affect the instantaneous firing rate in a boiler. Also the characteristics of the fuels have to be taken into consideration when designing boiler control systems. When co-firing two fuels with clearly distinct combustion characteristics, direct assumptions based on each fuel's characteristies cannot be made about combustion behaviour of their mixture. Combustion experiments with coal and wood chips and their co-firing were carried out in a pilot-scale CFB reactor (VTT) and a large-scale CFB boiler (Chalmers). A comparison of the combustion in the two different size reactors, provides information about scaling. The combustion responses due to changes in the fuel feeding of the two circulating fluidized beds are analyzed by a dynamic model. (c) 2007 Elsevier Ltd. All rights reserved.
650 7a TEKNIK OCH TEKNOLOGIERx Annan teknikx Övrig annan teknik0 (SwePub)211992 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Other Engineering and Technologiesx Other Engineering and Technologies not elsewhere specified0 (SwePub)211992 hsv//eng
653 a MODEL
653 a SIMULATION
653 a CFBC
653 a COCOMBUSTION
653 a dynamics
653 a BOILERS
653 a fuel mixtures
653 a COMBUSTION
700a Jegoroff, M.u Teknologian Tutkimuskeskus (VTT),Technical Research Centre of Finland (VTT)4 aut
700a Saastamoinen, J.u Teknologian Tutkimuskeskus (VTT),Technical Research Centre of Finland (VTT)4 aut
700a Tourunen, A.u Teknologian Tutkimuskeskus (VTT),Technical Research Centre of Finland (VTT)4 aut
700a Jantti, T.4 aut
700a Kettunen, A.4 aut
700a Johnsson, Filip,d 1960u Chalmers tekniska högskola,Chalmers University of Technology4 aut0 (Swepub:cth)fijo
700a Niklasson, Fredrik,d 1972u Chalmers tekniska högskola,Chalmers University of Technology4 aut
710a Teknologian Tutkimuskeskus (VTT)b Chalmers tekniska högskola4 org
773t Fueld : Elsevier BVg 86:14, s. 2043-2051q 86:14<2043-2051x 0016-2361
856u http://dx.doi.org/10.1016/j.fuel.2007.04.006y FULLTEXT
8564 8u https://research.chalmers.se/publication/77723
8564 8u https://doi.org/10.1016/j.fuel.2007.04.006

Hitta via bibliotek

  • Fuel (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy