SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:3892a16e-f82c-49d8-a7e3-2e9ef1691fb8"
 

Sökning: id:"swepub:oai:research.chalmers.se:3892a16e-f82c-49d8-a7e3-2e9ef1691fb8" > Microfluidic biosen...

Microfluidic biosensor for the detection of DNA by fluorescence enhancement and the following streptavidin detection by fluorescence quenching

Wang, Jun, 1976 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Aki, Michihiko (författare)
Fujitsu FTP Corporation
Onoshima, Daisuke (författare)
Nagoya University
visa fler...
Arinaga, Kenji (författare)
Fujitsu FTP Corporation
Kaji, Noritada (författare)
Nagoya University,Fujitsu FTP Corporation
Tokeshi, Manabu (författare)
Hokkaido University,Nagoya University
Fujita, Shozo (författare)
Fujitsu FTP Corporation
Yokoyama, Naoki (författare)
Fujitsu FTP Corporation
Baba, Yoshinobu (författare)
Nagoya University,National Institute of Advanced Industrial Science and Technology (AIST)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2014
2014
Engelska.
Ingår i: Biosensors and Bioelectronics. - : Elsevier BV. - 0956-5663 .- 1873-4235. ; 51, s. 280-285
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We reported an optical DNA/protein microfluidic sensor which consists of single stranded (ss) DNA-Cy3 probes on gold surface and simple line-shape microfluidic channel. These ssDNA-Cy3 probes with random sequence in bulk solution or on gold surface exhibits fluorescence enhancement after binding with complementary ssDNA (cssDNA) targets. Particularly it did not require complicated design or hairpin-like stem-loop conformation, which made it easier to be made and applied in analytes detection by fluorescence switching techniques. Using ssDNA-cy3 probes attached on gold surface in a microfluidic channel, strong fluorescence enhancement was measured by ssDNA with cssDNA binding or ssDNA with cssDNA-biotin binding. The following introduction of streptavidin resulted in fluorescence quenching (fluorescence decrease) because of the binding of hybridized DNA-biotin with streptavidin. This sensor showed strong affinity and high sensitivity toward the streptavidin, the minimum detectable concentration for streptavidin was 1 pM, equating to an absolute detection limit of 60 amol in this microfluidic channel. Microfluidic channel height and flow rate is optimized to increase surface reaction efficiency and fluorescence switching efficiency. In contrast to previously reported optical molecular beacon approach, this sensor can be used not only for the detection of cssDNA target, but also for the detection of streptavidin. This microfluidic sensor offers the promise of analyzing kinds of molecular targets or immunoreactions.

Ämnesord

NATURVETENSKAP  -- Biologi -- Biofysik (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biophysics (hsv//eng)

Nyckelord

probes
binding proteins
interrogation
hybridization
analysis systems
sensitive detection
nucleic-acid
thiazole orange
molecular-beacon
electron-transfer

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy